Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system

Due to the increasing awareness of the health benefits associated with the use of air humidification and its significance in other high-tech industries, an experimental and theoretical study was carried out to estimate humidification load in a convective heat transfer in water-air-vapour system. A s...

Full description

Saved in:
Bibliographic Details
Main Authors: Iyuke, S.E., Mohamad, A.B., Daud, W.R.W.
Format: Article
Published: Elsevier 2001
Online Access:http://psasir.upm.edu.my/id/eprint/114141/
https://linkinghub.elsevier.com/retrieve/pii/S0009250901001373
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.upm.eprints.114141
record_format eprints
spelling my.upm.eprints.1141412024-12-03T08:18:35Z http://psasir.upm.edu.my/id/eprint/114141/ Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system Iyuke, S.E. Mohamad, A.B. Daud, W.R.W. Due to the increasing awareness of the health benefits associated with the use of air humidification and its significance in other high-tech industries, an experimental and theoretical study was carried out to estimate humidification load in a convective heat transfer in water-air-vapour system. A simple gas bubbling method was employed for the experiments, while several models were developed to account for the applicability of the experimental data. The results showed agreement between the measured and the calculated data, and both purported that the humidification unit can be run successfully with airflow of 10-200 ml/min at the temperatures of 26-90°C. However, as from 300 to 1000 ml/min, the optimum operating temperatures decreased from 90°C to 35°C at 2 atm. At the operating conditions, the unit achieved relative humidity between 54% and 90% within the airflow of 10-1000 ml/min. The proposed unit characterisation method indicated a future advancement academically and industrially in this narrow but important subject matter. Elsevier 2001-08 Article PeerReviewed Iyuke, S.E. and Mohamad, A.B. and Daud, W.R.W. (2001) Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system. Chemical Engineering Science, 56 (16). pp. 4949-4956. ISSN 0009-2509; eISSN: 0009-2509 https://linkinghub.elsevier.com/retrieve/pii/S0009250901001373 10.1016/s0009-2509(01)00137-3
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description Due to the increasing awareness of the health benefits associated with the use of air humidification and its significance in other high-tech industries, an experimental and theoretical study was carried out to estimate humidification load in a convective heat transfer in water-air-vapour system. A simple gas bubbling method was employed for the experiments, while several models were developed to account for the applicability of the experimental data. The results showed agreement between the measured and the calculated data, and both purported that the humidification unit can be run successfully with airflow of 10-200 ml/min at the temperatures of 26-90°C. However, as from 300 to 1000 ml/min, the optimum operating temperatures decreased from 90°C to 35°C at 2 atm. At the operating conditions, the unit achieved relative humidity between 54% and 90% within the airflow of 10-1000 ml/min. The proposed unit characterisation method indicated a future advancement academically and industrially in this narrow but important subject matter.
format Article
author Iyuke, S.E.
Mohamad, A.B.
Daud, W.R.W.
spellingShingle Iyuke, S.E.
Mohamad, A.B.
Daud, W.R.W.
Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system
author_facet Iyuke, S.E.
Mohamad, A.B.
Daud, W.R.W.
author_sort Iyuke, S.E.
title Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system
title_short Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system
title_full Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system
title_fullStr Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system
title_full_unstemmed Estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system
title_sort estimation of humidification load from humidifier column by convective heat transfer in water–air–vapour system
publisher Elsevier
publishDate 2001
url http://psasir.upm.edu.my/id/eprint/114141/
https://linkinghub.elsevier.com/retrieve/pii/S0009250901001373
_version_ 1817844705616986112
score 13.223943