Comparative study of partial discharge localisation techniques within transformer windings

Partial discharge (PD) activity may occur inside power transformers and the existence of this activity produces a negative effect on the transformer until eventually there is catastrophic failure. Therefore, partial discharge detection and measurement within a transformer winding have become an impo...

Full description

Saved in:
Bibliographic Details
Main Authors: Abd Rahman, M.S., Lewin, P.L., Rapisarda, P.
Format:
Published: 2018
Online Access:http://dspace.uniten.edu.my/jspui/handle/123456789/9535
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-9535
record_format dspace
spelling my.uniten.dspace-95352018-03-01T04:55:01Z Comparative study of partial discharge localisation techniques within transformer windings Abd Rahman, M.S. Lewin, P.L. Rapisarda, P. Partial discharge (PD) activity may occur inside power transformers and the existence of this activity produces a negative effect on the transformer until eventually there is catastrophic failure. Therefore, partial discharge detection and measurement within a transformer winding have become an important research area to provide asset health information enabling the maintenance and replacement processes to be carried out effectively. A modern condition monitoring system for PD activity inside HV transformers may use any observable phenomena but here we concentrate on an electrical detection method. The fundamental localization technique uses wavelet multi-resolution analysis for calculating the energy at different frequency ranges and Principal Component Analysis as dimensional reduction tool that produces the output that ultimately can be used as an indicator of PD location inside a transformer winding. However, an alternative method has been developed to using corresponding 3 dimensional filters to enable the localisation process. Both approaches are compared and obtained results are presented in this paper. © 2015 IEEE. 2018-03-01T04:55:01Z 2018-03-01T04:55:01Z 2015 http://dspace.uniten.edu.my/jspui/handle/123456789/9535
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Partial discharge (PD) activity may occur inside power transformers and the existence of this activity produces a negative effect on the transformer until eventually there is catastrophic failure. Therefore, partial discharge detection and measurement within a transformer winding have become an important research area to provide asset health information enabling the maintenance and replacement processes to be carried out effectively. A modern condition monitoring system for PD activity inside HV transformers may use any observable phenomena but here we concentrate on an electrical detection method. The fundamental localization technique uses wavelet multi-resolution analysis for calculating the energy at different frequency ranges and Principal Component Analysis as dimensional reduction tool that produces the output that ultimately can be used as an indicator of PD location inside a transformer winding. However, an alternative method has been developed to using corresponding 3 dimensional filters to enable the localisation process. Both approaches are compared and obtained results are presented in this paper. © 2015 IEEE.
format
author Abd Rahman, M.S.
Lewin, P.L.
Rapisarda, P.
spellingShingle Abd Rahman, M.S.
Lewin, P.L.
Rapisarda, P.
Comparative study of partial discharge localisation techniques within transformer windings
author_facet Abd Rahman, M.S.
Lewin, P.L.
Rapisarda, P.
author_sort Abd Rahman, M.S.
title Comparative study of partial discharge localisation techniques within transformer windings
title_short Comparative study of partial discharge localisation techniques within transformer windings
title_full Comparative study of partial discharge localisation techniques within transformer windings
title_fullStr Comparative study of partial discharge localisation techniques within transformer windings
title_full_unstemmed Comparative study of partial discharge localisation techniques within transformer windings
title_sort comparative study of partial discharge localisation techniques within transformer windings
publishDate 2018
url http://dspace.uniten.edu.my/jspui/handle/123456789/9535
_version_ 1644494739003670528
score 13.160551