An experimental method for effusivity determination of different scratched temperature sensors

This paper presents an experimental method for evaluating the effusivity values of different scratched temperature sensors. These sensors have a response time on the order of microseconds (50 μs) with a rise time less than (0.3 μs). Two types of scratch were used, mainly abrasive papers with differe...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohammed, H., Salleh, H., Yusoff, M.Z.
Format:
Published: 2018
Online Access:http://dspace.uniten.edu.my/jspui/handle/123456789/7438
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-7438
record_format dspace
spelling my.uniten.dspace-74382018-02-19T07:40:23Z An experimental method for effusivity determination of different scratched temperature sensors Mohammed, H. Salleh, H. Yusoff, M.Z. This paper presents an experimental method for evaluating the effusivity values of different scratched temperature sensors. These sensors have a response time on the order of microseconds (50 μs) with a rise time less than (0.3 μs). Two types of scratch were used, mainly abrasive papers with different grit sizes and scalpel blades with different thicknesses to form the sensor junction. The effect of scratch technique on the sensor's effusivity is also investigated. The sensors were tested and calibrated in the test section of a shock tube facility at different operating conditions. It was observed that the effusivity of a particular sensor depends on the Mach number, scratch technique, junction location as well as on the enthalpy condition. It was also noticed that sensor scratched using scalpel blade technique does not require an individual calibration. However, for sensor scratched using abrasive paper technique, a calibration for each sensor is likely to be required. The present results have provided useful and practical data of the effusivity values for different scratched temperature sensors. These data are beneficial to the experimentalists in the field and it can be used for accurate transient heat transfer rate measurements. ©2009 IEEE. 2018-01-11T09:44:48Z 2018-01-11T09:44:48Z 2009 http://dspace.uniten.edu.my/jspui/handle/123456789/7438
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description This paper presents an experimental method for evaluating the effusivity values of different scratched temperature sensors. These sensors have a response time on the order of microseconds (50 μs) with a rise time less than (0.3 μs). Two types of scratch were used, mainly abrasive papers with different grit sizes and scalpel blades with different thicknesses to form the sensor junction. The effect of scratch technique on the sensor's effusivity is also investigated. The sensors were tested and calibrated in the test section of a shock tube facility at different operating conditions. It was observed that the effusivity of a particular sensor depends on the Mach number, scratch technique, junction location as well as on the enthalpy condition. It was also noticed that sensor scratched using scalpel blade technique does not require an individual calibration. However, for sensor scratched using abrasive paper technique, a calibration for each sensor is likely to be required. The present results have provided useful and practical data of the effusivity values for different scratched temperature sensors. These data are beneficial to the experimentalists in the field and it can be used for accurate transient heat transfer rate measurements. ©2009 IEEE.
format
author Mohammed, H.
Salleh, H.
Yusoff, M.Z.
spellingShingle Mohammed, H.
Salleh, H.
Yusoff, M.Z.
An experimental method for effusivity determination of different scratched temperature sensors
author_facet Mohammed, H.
Salleh, H.
Yusoff, M.Z.
author_sort Mohammed, H.
title An experimental method for effusivity determination of different scratched temperature sensors
title_short An experimental method for effusivity determination of different scratched temperature sensors
title_full An experimental method for effusivity determination of different scratched temperature sensors
title_fullStr An experimental method for effusivity determination of different scratched temperature sensors
title_full_unstemmed An experimental method for effusivity determination of different scratched temperature sensors
title_sort experimental method for effusivity determination of different scratched temperature sensors
publishDate 2018
url http://dspace.uniten.edu.my/jspui/handle/123456789/7438
_version_ 1644494195038093312
score 13.160551