Energy analysis of cooling pump in internal combustion engine
This study is conducted to analyze the energy use by cooling pump in internal combustion engine (ICE). The main focus of the experiment is to analyze the radiator heat transfer and the cooling pump power. The heat transfer rate of radiator is determined by conducting an experiment on an ICE. Thermoc...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | |
Published: |
2017
|
Online Access: | http://dspace.uniten.edu.my/jspui/handle/123456789/6241 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-6241 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-62412017-12-08T09:12:19Z Energy analysis of cooling pump in internal combustion engine Mahlia, T.M.I. Husnawan, M. Masjuki, H.H. Chow, K.V. Low, T.S. Liaw, A.W.J. This study is conducted to analyze the energy use by cooling pump in internal combustion engine (ICE). The main focus of the experiment is to analyze the radiator heat transfer and the cooling pump power. The heat transfer rate of radiator is determined by conducting an experiment on an ICE. Thermocouples and an anemometer are used for temperature and air velocity measurement respectively. The cooling pump power is determined through dynamometer test. These experiments are conducted only for engine speed range of 1000rpm to 1500rpm to avoid overheating when belt is dismantled. The engine running at 1000rpm to 1500rpm produces about 1.2kW to 2.5kW power and rejects heat at rate of 0.20kW to 0.3kW, representing 13.0% to 19.1% of the total energy lost. The cooling pump power is approximately 0.13-0.19kW which is approximately 7.6% of the engine power output. Copyright © 2008 by ASME. 2017-12-08T09:12:19Z 2017-12-08T09:12:19Z 2009 http://dspace.uniten.edu.my/jspui/handle/123456789/6241 |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
This study is conducted to analyze the energy use by cooling pump in internal combustion engine (ICE). The main focus of the experiment is to analyze the radiator heat transfer and the cooling pump power. The heat transfer rate of radiator is determined by conducting an experiment on an ICE. Thermocouples and an anemometer are used for temperature and air velocity measurement respectively. The cooling pump power is determined through dynamometer test. These experiments are conducted only for engine speed range of 1000rpm to 1500rpm to avoid overheating when belt is dismantled. The engine running at 1000rpm to 1500rpm produces about 1.2kW to 2.5kW power and rejects heat at rate of 0.20kW to 0.3kW, representing 13.0% to 19.1% of the total energy lost. The cooling pump power is approximately 0.13-0.19kW which is approximately 7.6% of the engine power output. Copyright © 2008 by ASME. |
format |
|
author |
Mahlia, T.M.I. Husnawan, M. Masjuki, H.H. Chow, K.V. Low, T.S. Liaw, A.W.J. |
spellingShingle |
Mahlia, T.M.I. Husnawan, M. Masjuki, H.H. Chow, K.V. Low, T.S. Liaw, A.W.J. Energy analysis of cooling pump in internal combustion engine |
author_facet |
Mahlia, T.M.I. Husnawan, M. Masjuki, H.H. Chow, K.V. Low, T.S. Liaw, A.W.J. |
author_sort |
Mahlia, T.M.I. |
title |
Energy analysis of cooling pump in internal combustion engine |
title_short |
Energy analysis of cooling pump in internal combustion engine |
title_full |
Energy analysis of cooling pump in internal combustion engine |
title_fullStr |
Energy analysis of cooling pump in internal combustion engine |
title_full_unstemmed |
Energy analysis of cooling pump in internal combustion engine |
title_sort |
energy analysis of cooling pump in internal combustion engine |
publishDate |
2017 |
url |
http://dspace.uniten.edu.my/jspui/handle/123456789/6241 |
_version_ |
1644493883148599296 |
score |
13.214268 |