Hybrid diesel/PV system sizing and cost estimation

This paper presents a hybrid diesel/PV system cost study and sizing analysis for a hypothetical system in Kuala Terengganu, Malaysia. The hybrid generation is to support a 2MVA load as a standalone network. Diesel generator ratings followed the ISO 8528. The maximum size of the PV system is selected...

Full description

Saved in:
Bibliographic Details
Main Authors: Belhamadia, A., Mansor, M., Younis, M.
Format: Article
Language:en_US
Published: 2017
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-5931
record_format dspace
spelling my.uniten.dspace-59312018-01-18T07:01:51Z Hybrid diesel/PV system sizing and cost estimation Belhamadia, A. Mansor, M. Younis, M. This paper presents a hybrid diesel/PV system cost study and sizing analysis for a hypothetical system in Kuala Terengganu, Malaysia. The hybrid generation is to support a 2MVA load as a standalone network. Diesel generator ratings followed the ISO 8528. The maximum size of the PV system is selected such that its penetration level does not exceed 25%. NEC 690 standards were followedin selecting the maximum and minimum numbers of modules. Cost estimation is carried out using Hybrid Optimization Model for Electric Renewable (HOMER). The results show that the mostefficient size of the PV system is 400kW<inf>p</inf>among other alternatives and based on the connection configuration a theoretical maximum power of 387.6kW<inf>p</inf> would be generated from the system. 2017-12-08T07:41:18Z 2017-12-08T07:41:18Z 2014 Article 10.1049/cp.2014.1506 en_US Hybrid diesel/PV system sizing and cost estimation. In IET Seminar Digest (CP659 ed., Vol. 2014). Institution of Engineering and Technology.
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language en_US
description This paper presents a hybrid diesel/PV system cost study and sizing analysis for a hypothetical system in Kuala Terengganu, Malaysia. The hybrid generation is to support a 2MVA load as a standalone network. Diesel generator ratings followed the ISO 8528. The maximum size of the PV system is selected such that its penetration level does not exceed 25%. NEC 690 standards were followedin selecting the maximum and minimum numbers of modules. Cost estimation is carried out using Hybrid Optimization Model for Electric Renewable (HOMER). The results show that the mostefficient size of the PV system is 400kW<inf>p</inf>among other alternatives and based on the connection configuration a theoretical maximum power of 387.6kW<inf>p</inf> would be generated from the system.
format Article
author Belhamadia, A.
Mansor, M.
Younis, M.
spellingShingle Belhamadia, A.
Mansor, M.
Younis, M.
Hybrid diesel/PV system sizing and cost estimation
author_facet Belhamadia, A.
Mansor, M.
Younis, M.
author_sort Belhamadia, A.
title Hybrid diesel/PV system sizing and cost estimation
title_short Hybrid diesel/PV system sizing and cost estimation
title_full Hybrid diesel/PV system sizing and cost estimation
title_fullStr Hybrid diesel/PV system sizing and cost estimation
title_full_unstemmed Hybrid diesel/PV system sizing and cost estimation
title_sort hybrid diesel/pv system sizing and cost estimation
publishDate 2017
_version_ 1644493803250253824
score 13.214268