In house calibration of pd detector system for field test result reliability
Partial Discharge is a phenomenon that indicates cables or joints deterioration in an electrical transmission or distribution system. Mechanical damages, voids or contamination in the insulation of cables or joints may contribute to the degradation thus emission of PD is present. The electromagnetic...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | en_US |
Published: |
2017
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-5674 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-56742017-12-12T03:14:28Z In house calibration of pd detector system for field test result reliability Raj, A. Chakrabarty, C.K. Ismail, R. Ghani, B.A. Partial Discharge is a phenomenon that indicates cables or joints deterioration in an electrical transmission or distribution system. Mechanical damages, voids or contamination in the insulation of cables or joints may contribute to the degradation thus emission of PD is present. The electromagnetic pulses emitted may represent the condition of the insulation. Current PD detector designed using Patch Antenna with combination of FPGA and ADC is capable to pinpoint the PD source however to ensure the reproducibility between PD detectors, a calibration method has to be established. © 2006-2016 Asian Research Publishing Network (ARPN). 2017-12-08T06:45:15Z 2017-12-08T06:45:15Z 2016 Article https://www.scopus.com/record/display.uri?eid=2-s2.0-84971441783&origin=resultslist&sort=plf-f&src=s&sid=6cfeb1caade6576bd5b9e7f8e80e6090&sot en_US ARPN Journal of Engineering and Applied SciencesOpen Access Volume 11, Issue 10, 20 May 2016, Pages 6279-6283 |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
en_US |
description |
Partial Discharge is a phenomenon that indicates cables or joints deterioration in an electrical transmission or distribution system. Mechanical damages, voids or contamination in the insulation of cables or joints may contribute to the degradation thus emission of PD is present. The electromagnetic pulses emitted may represent the condition of the insulation. Current PD detector designed using Patch Antenna with combination of FPGA and ADC is capable to pinpoint the PD source however to ensure the reproducibility between PD detectors, a calibration method has to be established. © 2006-2016 Asian Research Publishing Network (ARPN). |
format |
Article |
author |
Raj, A. Chakrabarty, C.K. Ismail, R. Ghani, B.A. |
spellingShingle |
Raj, A. Chakrabarty, C.K. Ismail, R. Ghani, B.A. In house calibration of pd detector system for field test result reliability |
author_facet |
Raj, A. Chakrabarty, C.K. Ismail, R. Ghani, B.A. |
author_sort |
Raj, A. |
title |
In house calibration of pd detector system for field test result reliability |
title_short |
In house calibration of pd detector system for field test result reliability |
title_full |
In house calibration of pd detector system for field test result reliability |
title_fullStr |
In house calibration of pd detector system for field test result reliability |
title_full_unstemmed |
In house calibration of pd detector system for field test result reliability |
title_sort |
in house calibration of pd detector system for field test result reliability |
publishDate |
2017 |
_version_ |
1644493748482080768 |
score |
13.214268 |