In house calibration of pd detector system for field test result reliability

Partial Discharge is a phenomenon that indicates cables or joints deterioration in an electrical transmission or distribution system. Mechanical damages, voids or contamination in the insulation of cables or joints may contribute to the degradation thus emission of PD is present. The electromagnetic...

Full description

Saved in:
Bibliographic Details
Main Authors: Raj, A., Chakrabarty, C.K., Ismail, R., Ghani, B.A.
Format: Article
Language:en_US
Published: 2017
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-5674
record_format dspace
spelling my.uniten.dspace-56742017-12-12T03:14:28Z In house calibration of pd detector system for field test result reliability Raj, A. Chakrabarty, C.K. Ismail, R. Ghani, B.A. Partial Discharge is a phenomenon that indicates cables or joints deterioration in an electrical transmission or distribution system. Mechanical damages, voids or contamination in the insulation of cables or joints may contribute to the degradation thus emission of PD is present. The electromagnetic pulses emitted may represent the condition of the insulation. Current PD detector designed using Patch Antenna with combination of FPGA and ADC is capable to pinpoint the PD source however to ensure the reproducibility between PD detectors, a calibration method has to be established. © 2006-2016 Asian Research Publishing Network (ARPN). 2017-12-08T06:45:15Z 2017-12-08T06:45:15Z 2016 Article https://www.scopus.com/record/display.uri?eid=2-s2.0-84971441783&origin=resultslist&sort=plf-f&src=s&sid=6cfeb1caade6576bd5b9e7f8e80e6090&sot en_US ARPN Journal of Engineering and Applied SciencesOpen Access Volume 11, Issue 10, 20 May 2016, Pages 6279-6283
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language en_US
description Partial Discharge is a phenomenon that indicates cables or joints deterioration in an electrical transmission or distribution system. Mechanical damages, voids or contamination in the insulation of cables or joints may contribute to the degradation thus emission of PD is present. The electromagnetic pulses emitted may represent the condition of the insulation. Current PD detector designed using Patch Antenna with combination of FPGA and ADC is capable to pinpoint the PD source however to ensure the reproducibility between PD detectors, a calibration method has to be established. © 2006-2016 Asian Research Publishing Network (ARPN).
format Article
author Raj, A.
Chakrabarty, C.K.
Ismail, R.
Ghani, B.A.
spellingShingle Raj, A.
Chakrabarty, C.K.
Ismail, R.
Ghani, B.A.
In house calibration of pd detector system for field test result reliability
author_facet Raj, A.
Chakrabarty, C.K.
Ismail, R.
Ghani, B.A.
author_sort Raj, A.
title In house calibration of pd detector system for field test result reliability
title_short In house calibration of pd detector system for field test result reliability
title_full In house calibration of pd detector system for field test result reliability
title_fullStr In house calibration of pd detector system for field test result reliability
title_full_unstemmed In house calibration of pd detector system for field test result reliability
title_sort in house calibration of pd detector system for field test result reliability
publishDate 2017
_version_ 1644493748482080768
score 13.214268