Vibration Effect to Kenyir Dam Intake Section During a Spill Event

Kenyir Dam located in Terengganu, Malaysia is a hydropower dam which served the purpose of generating electricity to the surrounding areas. Water is basically flown from the upstream to downstream area through the intake and pressure tunnel sections. In some cases, due to large volume of water, the...

Full description

Saved in:
Bibliographic Details
Main Authors: Hassan N.H., Zawawi M.H., Mazlan A.Z.A., Arbain A., Abas M.A.
Other Authors: 57204683370
Format: Conference paper
Published: Springer Science and Business Media Deutschland GmbH 2025
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-37179
record_format dspace
spelling my.uniten.dspace-371792025-03-03T15:48:19Z Vibration Effect to Kenyir Dam Intake Section During a Spill Event Hassan N.H. Zawawi M.H. Mazlan A.Z.A. Arbain A. Abas M.A. 57204683370 39162217600 57216895962 57213160085 56893346700 Flow of water Frequency domain analysis Hazardous materials spills Natural frequencies Rivers Water levels Dam structure Downstream areas Hydropower dams Intake Malaysia Pressure tunnel Tunnel sections Vibration Vibration effect Water spilling Dams Kenyir Dam located in Terengganu, Malaysia is a hydropower dam which served the purpose of generating electricity to the surrounding areas. Water is basically flown from the upstream to downstream area through the intake and pressure tunnel sections. In some cases, due to large volume of water, the dam structure might experience significant vibration effect from water spill event. In this study, the flow-induced vibration during critical water spilling of 148�m water level at intake section of Kenyir Dam is investigated using ANSYS software. The results from both frequency domain and operational deflection shapes (ODS) are compared with the natural frequencies and mode shapes of the dam, in order to determine the safety precautions during dam operating condition. From the results of water level 148�m, the transient vibration response from the water flow is occurred at operating frequency of 2.745�Hz. There is no resonance phenomenon during this water spilling condition since the natural frequency of the intake section occurred at 3.5�Hz. However, some precautions should be taken since the deflection shapes of the dam structure might be higher above this water level. ? The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd 2024. Final 2025-03-03T07:48:19Z 2025-03-03T07:48:19Z 2024 Conference paper 10.1007/978-981-99-6026-2_40 2-s2.0-85181984544 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85181984544&doi=10.1007%2f978-981-99-6026-2_40&partnerID=40&md5=12a124750e980ced9e3fe2cf1c7c9653 https://irepository.uniten.edu.my/handle/123456789/37179 386 545 552 Springer Science and Business Media Deutschland GmbH Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Flow of water
Frequency domain analysis
Hazardous materials spills
Natural frequencies
Rivers
Water levels
Dam structure
Downstream areas
Hydropower dams
Intake
Malaysia
Pressure tunnel
Tunnel sections
Vibration
Vibration effect
Water spilling
Dams
spellingShingle Flow of water
Frequency domain analysis
Hazardous materials spills
Natural frequencies
Rivers
Water levels
Dam structure
Downstream areas
Hydropower dams
Intake
Malaysia
Pressure tunnel
Tunnel sections
Vibration
Vibration effect
Water spilling
Dams
Hassan N.H.
Zawawi M.H.
Mazlan A.Z.A.
Arbain A.
Abas M.A.
Vibration Effect to Kenyir Dam Intake Section During a Spill Event
description Kenyir Dam located in Terengganu, Malaysia is a hydropower dam which served the purpose of generating electricity to the surrounding areas. Water is basically flown from the upstream to downstream area through the intake and pressure tunnel sections. In some cases, due to large volume of water, the dam structure might experience significant vibration effect from water spill event. In this study, the flow-induced vibration during critical water spilling of 148�m water level at intake section of Kenyir Dam is investigated using ANSYS software. The results from both frequency domain and operational deflection shapes (ODS) are compared with the natural frequencies and mode shapes of the dam, in order to determine the safety precautions during dam operating condition. From the results of water level 148�m, the transient vibration response from the water flow is occurred at operating frequency of 2.745�Hz. There is no resonance phenomenon during this water spilling condition since the natural frequency of the intake section occurred at 3.5�Hz. However, some precautions should be taken since the deflection shapes of the dam structure might be higher above this water level. ? The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd 2024.
author2 57204683370
author_facet 57204683370
Hassan N.H.
Zawawi M.H.
Mazlan A.Z.A.
Arbain A.
Abas M.A.
format Conference paper
author Hassan N.H.
Zawawi M.H.
Mazlan A.Z.A.
Arbain A.
Abas M.A.
author_sort Hassan N.H.
title Vibration Effect to Kenyir Dam Intake Section During a Spill Event
title_short Vibration Effect to Kenyir Dam Intake Section During a Spill Event
title_full Vibration Effect to Kenyir Dam Intake Section During a Spill Event
title_fullStr Vibration Effect to Kenyir Dam Intake Section During a Spill Event
title_full_unstemmed Vibration Effect to Kenyir Dam Intake Section During a Spill Event
title_sort vibration effect to kenyir dam intake section during a spill event
publisher Springer Science and Business Media Deutschland GmbH
publishDate 2025
_version_ 1826077628126199808
score 13.244413