Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete

Concrete-filled steel tube (CFST) columns that experience outward local buckling under high axial stress remain a significant concern, particularly when thin steel sections are used, as opposed to semi-compact and compact sections. This study investigated the performance of column systems by compari...

Full description

Saved in:
Bibliographic Details
Main Authors: Jasim A.M.D.A., Wong L.S., Al-Zand A.W., Kong S.Y.
Other Authors: 58749165500
Format: Article
Published: Salehan Institute of Higher Education 2025
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-36825
record_format dspace
spelling my.uniten.dspace-368252025-03-03T15:44:57Z Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete Jasim A.M.D.A. Wong L.S. Al-Zand A.W. Kong S.Y. 58749165500 55504782500 56512113100 57208875766 Concrete-filled steel tube (CFST) columns that experience outward local buckling under high axial stress remain a significant concern, particularly when thin steel sections are used, as opposed to semi-compact and compact sections. This study investigated the performance of column systems by comparing single-and double-C-section configurations with both hollow and concrete-filled designs. Two types of infill materials were investigated: normal concrete and recycled material concrete, which included 10% waste glass powder as a cement replacement, 8% black high-density polyethylene beads as a sand substitute, and 10% pumice stone as coarse aggregate. To enhance the strength of the proposed CFS column, steel strips and screws were used to connect the flanges of the C-sections. Nine columns were tested experimentally under static axial load. Additionally, finite element analysis software was used to model and evaluate the effects of parameters beyond those investigated in the tests. The results indicated that the load capacity of the double face-to-face section was approximately 3% higher than that of the double back-to-back section. The addition of steel strips, used to connect the lips of the C-section flanges, enhanced the axial strength of the column by approximately 2% compared with the unstrengthened corresponding specimen and delayed buckling in the most vulnerable areas. Furthermore, the recycled infill concrete material had a minimal impact on the axial performance of the analyzed CFS columns compared to the control concrete, with a difference of less than 2.2%. The findings confirm that recycled waste material concrete can achieve performance comparable to that of the conventional concrete. ? 2024 by the authors. Final 2025-03-03T07:44:57Z 2025-03-03T07:44:57Z 2024 Article 10.28991/CEJ-SP2024-010-014 2-s2.0-85216301912 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85216301912&doi=10.28991%2fCEJ-SP2024-010-014&partnerID=40&md5=69d83f615ec9bd25af0bc59cfff6c2a8 https://irepository.uniten.edu.my/handle/123456789/36825 10 271 290 Salehan Institute of Higher Education Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Concrete-filled steel tube (CFST) columns that experience outward local buckling under high axial stress remain a significant concern, particularly when thin steel sections are used, as opposed to semi-compact and compact sections. This study investigated the performance of column systems by comparing single-and double-C-section configurations with both hollow and concrete-filled designs. Two types of infill materials were investigated: normal concrete and recycled material concrete, which included 10% waste glass powder as a cement replacement, 8% black high-density polyethylene beads as a sand substitute, and 10% pumice stone as coarse aggregate. To enhance the strength of the proposed CFS column, steel strips and screws were used to connect the flanges of the C-sections. Nine columns were tested experimentally under static axial load. Additionally, finite element analysis software was used to model and evaluate the effects of parameters beyond those investigated in the tests. The results indicated that the load capacity of the double face-to-face section was approximately 3% higher than that of the double back-to-back section. The addition of steel strips, used to connect the lips of the C-section flanges, enhanced the axial strength of the column by approximately 2% compared with the unstrengthened corresponding specimen and delayed buckling in the most vulnerable areas. Furthermore, the recycled infill concrete material had a minimal impact on the axial performance of the analyzed CFS columns compared to the control concrete, with a difference of less than 2.2%. The findings confirm that recycled waste material concrete can achieve performance comparable to that of the conventional concrete. ? 2024 by the authors.
author2 58749165500
author_facet 58749165500
Jasim A.M.D.A.
Wong L.S.
Al-Zand A.W.
Kong S.Y.
format Article
author Jasim A.M.D.A.
Wong L.S.
Al-Zand A.W.
Kong S.Y.
spellingShingle Jasim A.M.D.A.
Wong L.S.
Al-Zand A.W.
Kong S.Y.
Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete
author_sort Jasim A.M.D.A.
title Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete
title_short Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete
title_full Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete
title_fullStr Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete
title_full_unstemmed Evaluating Axial Strength of Cold-formed C-Section Steel Columns Filled with Green High-performance Concrete
title_sort evaluating axial strength of cold-formed c-section steel columns filled with green high-performance concrete
publisher Salehan Institute of Higher Education
publishDate 2025
_version_ 1825816033707950080
score 13.244413