PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS
In this paper the effect of contamination under varying temperature and relative humidity (RH) in electrical electric motors? (EM) insulation is investigated through partial discharge (PD) diagnostics. The variations in PD intensity have been investigated under varying environmental conditions. For...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2025
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-36803 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-368032025-03-03T15:44:47Z PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS Hassan W. Hussain G.A. Firuzi K. Ariffin A.M. Kay J.A. 56038670200 57203105565 57969834100 16400722400 8853452700 Electric machine insulation Electric motors Partial discharges Petroleum tar Ambient stress Ambients Electric motor insulation Exposed to Industrial operations Motor insulation Partial discharge measurements Relative humidity Temperature and relative humidity Varying temperature Distribution functions In this paper the effect of contamination under varying temperature and relative humidity (RH) in electrical electric motors? (EM) insulation is investigated through partial discharge (PD) diagnostics. The variations in PD intensity have been investigated under varying environmental conditions. For this purpose, PD measurements were carried out within an artificial industrial environment inside a climate-controlled chamber. Various PD features were extracted to study probability distribution functions to further investigate the PD severity at various levels of contamination, under varying temperatures and RH. Based on the experimental outcomes, it was revealed that PD activity within the EM insulation was significantly affected by temperature and RH under varying contamination conditions. The proposed methodology is believed to be helpful in achieving the desired level of reliability for a wide range of industrial applications exposed to ambient stresses. ?2024 IEEE. Final 2025-03-03T07:44:47Z 2025-03-03T07:44:47Z 2024 Conference paper 10.1109/PCIC47799.2024.10832267 2-s2.0-85217165358 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85217165358&doi=10.1109%2fPCIC47799.2024.10832267&partnerID=40&md5=f36abcdbb793e393490579005780a6ff https://irepository.uniten.edu.my/handle/123456789/36803 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Electric machine insulation Electric motors Partial discharges Petroleum tar Ambient stress Ambients Electric motor insulation Exposed to Industrial operations Motor insulation Partial discharge measurements Relative humidity Temperature and relative humidity Varying temperature Distribution functions |
spellingShingle |
Electric machine insulation Electric motors Partial discharges Petroleum tar Ambient stress Ambients Electric motor insulation Exposed to Industrial operations Motor insulation Partial discharge measurements Relative humidity Temperature and relative humidity Varying temperature Distribution functions Hassan W. Hussain G.A. Firuzi K. Ariffin A.M. Kay J.A. PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS |
description |
In this paper the effect of contamination under varying temperature and relative humidity (RH) in electrical electric motors? (EM) insulation is investigated through partial discharge (PD) diagnostics. The variations in PD intensity have been investigated under varying environmental conditions. For this purpose, PD measurements were carried out within an artificial industrial environment inside a climate-controlled chamber. Various PD features were extracted to study probability distribution functions to further investigate the PD severity at various levels of contamination, under varying temperatures and RH. Based on the experimental outcomes, it was revealed that PD activity within the EM insulation was significantly affected by temperature and RH under varying contamination conditions. The proposed methodology is believed to be helpful in achieving the desired level of reliability for a wide range of industrial applications exposed to ambient stresses. ?2024 IEEE. |
author2 |
56038670200 |
author_facet |
56038670200 Hassan W. Hussain G.A. Firuzi K. Ariffin A.M. Kay J.A. |
format |
Conference paper |
author |
Hassan W. Hussain G.A. Firuzi K. Ariffin A.M. Kay J.A. |
author_sort |
Hassan W. |
title |
PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS |
title_short |
PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS |
title_full |
PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS |
title_fullStr |
PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS |
title_full_unstemmed |
PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS |
title_sort |
partial discharge diagnostics in electric motors exposed to ambient stresses during industrial operations |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2025 |
_version_ |
1825816284722364416 |
score |
13.244109 |