ARC flash assessment on 17kW photovoltaic system

TK1087.G62 2016

Saved in:
Bibliographic Details
Main Author: Gobinath Vijian
Format: text::Final Year Project
Language:English
Published: 2024
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-34957
record_format dspace
spelling my.uniten.dspace-349572024-11-10T02:02:08Z ARC flash assessment on 17kW photovoltaic system Gobinath Vijian Photovoltaic power system Photovoltaic power generation TK1087.G62 2016 This thesis presents arc flash analysis on AC system of a 17kW photovoltaic system in UNITEN. There might be an arc flash occurrence on the photovoltaic system when maintenance activities going. The workers are exposed to arc flash hazard if fault take place. The workers will get injuries when exposed to arc flash event. To create safer working environment, the workers need appropriate personnel protective equipment. Arc flash analysis for AC system is done on the photovoltaic system by simulating in ETAP software. This thesis present the procedure of using ETAP software to analyze single line diagram of the 17kW photovoltaic system. By using ETAP, the incident energy during arc flash occurrence calculated based on NFPA-70E standards. Based on the incident energy, appropriate PPE will be recommended to the workers. This is to ensure the workers is working in a safe environment. 2024-11-04T00:53:05Z 2024-11-04T00:53:05Z 2016 Resource Types::text::Final Year Project https://irepository.uniten.edu.my/handle/123456789/34957 en application/pdf
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
topic Photovoltaic power system
Photovoltaic power generation
spellingShingle Photovoltaic power system
Photovoltaic power generation
Gobinath Vijian
ARC flash assessment on 17kW photovoltaic system
description TK1087.G62 2016
format Resource Types::text::Final Year Project
author Gobinath Vijian
author_facet Gobinath Vijian
author_sort Gobinath Vijian
title ARC flash assessment on 17kW photovoltaic system
title_short ARC flash assessment on 17kW photovoltaic system
title_full ARC flash assessment on 17kW photovoltaic system
title_fullStr ARC flash assessment on 17kW photovoltaic system
title_full_unstemmed ARC flash assessment on 17kW photovoltaic system
title_sort arc flash assessment on 17kw photovoltaic system
publishDate 2024
_version_ 1817848153656786944
score 13.219503