Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis
The global photovoltaic (PV) capacity has expanded considerably, especially in buildings�and power plants that are stand-alone or�grid-connected PV systems. Further research into fault detection is required to identify various faults on different PV levels to keep the PV systems working at optimal e...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Springer Science and Business Media Deutschland GmbH
2024
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-34682 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-346822024-10-14T11:21:42Z Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis Hasan A.A.Q. Alkahtani A.A. Amin N. 57220644795 55646765500 7102424614 MATLAB/Simulink Parasitic resistance PV degradations PV faults Solar cell performance Fault detection Cell model I - V curve MATLAB/ SIMULINK Parasitic resistances Photovoltaic degradation Photovoltaic fault Photovoltaic systems Photovoltaics Solar cell performance Solar cells The global photovoltaic (PV) capacity has expanded considerably, especially in buildings�and power plants that are stand-alone or�grid-connected PV systems. Further research into fault detection is required to identify various faults on different PV levels to keep the PV systems working at optimal efficiency.�We provide a Simulink model of a single solar cell for estimating the current�voltage (I-V) properties of a real solar cell. The advantages and limitations of using the I-V curve as a diagnostic tool for PV system faults are discussed. In addition, the impact of series and shunt resistances on solar cell performance is highlighted and linked to related defects and degradation. Results of the proposed solar cell model confirmed its ability to mimic the real solar cell I-V curve with a very small percentage of error, around 1%. Furthermore, FF revealed the highest percentage of error of 1.2% due to the additional wire losses in real solar cell. Thus, the proposed solar cell model could be implemented to investigate degradations that have complex I-V curve behavior and improve the PV faults� monitoring systems. � 2023, The Author(s), under exclusive license to Springer Nature Switzerland AG. Final 2024-10-14T03:21:42Z 2024-10-14T03:21:42Z 2023 Conference Paper 10.1007/978-3-031-25274-7_56 2-s2.0-85150992855 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85150992855&doi=10.1007%2f978-3-031-25274-7_56&partnerID=40&md5=a84b62589ca7224f47f225d5ef10ea6b https://irepository.uniten.edu.my/handle/123456789/34682 584 LNNS 643 650 Springer Science and Business Media Deutschland GmbH Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
MATLAB/Simulink Parasitic resistance PV degradations PV faults Solar cell performance Fault detection Cell model I - V curve MATLAB/ SIMULINK Parasitic resistances Photovoltaic degradation Photovoltaic fault Photovoltaic systems Photovoltaics Solar cell performance Solar cells |
spellingShingle |
MATLAB/Simulink Parasitic resistance PV degradations PV faults Solar cell performance Fault detection Cell model I - V curve MATLAB/ SIMULINK Parasitic resistances Photovoltaic degradation Photovoltaic fault Photovoltaic systems Photovoltaics Solar cell performance Solar cells Hasan A.A.Q. Alkahtani A.A. Amin N. Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis |
description |
The global photovoltaic (PV) capacity has expanded considerably, especially in buildings�and power plants that are stand-alone or�grid-connected PV systems. Further research into fault detection is required to identify various faults on different PV levels to keep the PV systems working at optimal efficiency.�We provide a Simulink model of a single solar cell for estimating the current�voltage (I-V) properties of a real solar cell. The advantages and limitations of using the I-V curve as a diagnostic tool for PV system faults are discussed. In addition, the impact of series and shunt resistances on solar cell performance is highlighted and linked to related defects and degradation. Results of the proposed solar cell model confirmed its ability to mimic the real solar cell I-V curve with a very small percentage of error, around 1%. Furthermore, FF revealed the highest percentage of error of 1.2% due to the additional wire losses in real solar cell. Thus, the proposed solar cell model could be implemented to investigate degradations that have complex I-V curve behavior and improve the PV faults� monitoring systems. � 2023, The Author(s), under exclusive license to Springer Nature Switzerland AG. |
author2 |
57220644795 |
author_facet |
57220644795 Hasan A.A.Q. Alkahtani A.A. Amin N. |
format |
Conference Paper |
author |
Hasan A.A.Q. Alkahtani A.A. Amin N. |
author_sort |
Hasan A.A.Q. |
title |
Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis |
title_short |
Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis |
title_full |
Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis |
title_fullStr |
Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis |
title_full_unstemmed |
Modeling and Performance Evaluation of Solar Cells Using I-V Curve Analysis |
title_sort |
modeling and performance evaluation of solar cells using i-v curve analysis |
publisher |
Springer Science and Business Media Deutschland GmbH |
publishDate |
2024 |
_version_ |
1814061190287982592 |
score |
13.214268 |