Simulation of three phase shunt active power filter to mitigate harmonic current using simulink
TK3101 .G36 2016
Saved in:
Main Author: | |
---|---|
Format: | text::Final Year Project |
Language: | English |
Published: |
2024
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-33292 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-332922024-08-25T02:00:17Z Simulation of three phase shunt active power filter to mitigate harmonic current using simulink Gan, Chee Kai Harmonic analyzers TK3101 .G36 2016 Harmonic current is one of the main power quality issues happen in the plant industry nowadays. It is being produced by non-linear loads such as variable speed drive," induction motor, thyristor-based inverter etc. These non-linear loads normally employ the usage of power electronics device. This is undesirable as the harmonic current will damage equipment easily thus reducing the lifespan. The most common way to solve this problem is by using passive filter. However, it has undesirable downsides. 7 Therefore, this research focuses on mitigating the harmonic problem by designing a shunt active filter based on PQ Theory introduced by H. Akagi. This theory uses Clarke transformation and inverse of it to calculate the compensation current needed to inject to cancel the harmonic current produced at the load side. The simulation is done using Simulink software. From different cases studied, author can analyse the behaviour of waveforms and study the Total Harmonic Distortion obtained. 2024-08-22T04:25:44Z 2024-08-22T04:25:44Z 2016 Resource Types::text::Final Year Project https://irepository.uniten.edu.my/handle/123456789/33292 en application/pdf |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
language |
English |
topic |
Harmonic analyzers |
spellingShingle |
Harmonic analyzers Gan, Chee Kai Simulation of three phase shunt active power filter to mitigate harmonic current using simulink |
description |
TK3101 .G36 2016 |
format |
Resource Types::text::Final Year Project |
author |
Gan, Chee Kai |
author_facet |
Gan, Chee Kai |
author_sort |
Gan, Chee Kai |
title |
Simulation of three phase shunt active power filter to mitigate harmonic current using simulink |
title_short |
Simulation of three phase shunt active power filter to mitigate harmonic current using simulink |
title_full |
Simulation of three phase shunt active power filter to mitigate harmonic current using simulink |
title_fullStr |
Simulation of three phase shunt active power filter to mitigate harmonic current using simulink |
title_full_unstemmed |
Simulation of three phase shunt active power filter to mitigate harmonic current using simulink |
title_sort |
simulation of three phase shunt active power filter to mitigate harmonic current using simulink |
publishDate |
2024 |
_version_ |
1808979704764432384 |
score |
13.214268 |