spelling my.uniten.dspace-329192024-07-28T02:02:29Z Analysis of underground cable fault using time domain reflectometry technique Mohd Satari Mohamad Underground electric cables Fault location TA169.6.M63 2017 Cable fault phenomenon commonly occurs when the cable exceed their Dielectric Breakdown Strength (DBS) technically or the breakdown occurred because of the third party such as soil digging activities hit the cable and it can also happen due to the poor workmanship while installing the cable, especially underground cable. The experimental work was carried out to analyse the breakdown occurs on the cable due to a fault. Time Domain Reflectometry (TDR) was used to analyse the weakness point on the cable. The analysis is focusing on single core Cross-Linked Polyethylene (XLPE) High Voltage cable only. Pulses signal will be injected by TDR and it will propagate along the cable and the signal will be reflected back to the source when it reaches the miss-match impedance on the cable. The TDR experiment was conducted in High Voltage Laboratory in Tenaga Nasional Berhad Research (TNBR), Bangi. PSCAD software was used as the simulation element to replicate the TDR measurement. Pulse generator was built by using the mathematical expression on the PSCAD, it able to inject the pulses signal through the cable. The propagated signal will be reflected back to the source when miss-match impedance reached by the signal on the circuit module on the PSCAD. The result of signal reflections can be observed by using overlay graph on PSCAD. The analysis consists of the simulation on the various length of single cable, two cables and two cables with a resistor, inductor and capacitor placed in between of the cables to see the impact of the circuit module designed. 2024-07-25T03:15:03Z 2024-07-25T03:15:03Z 2017 Resource Types::text::Final Year Project https://irepository.uniten.edu.my/handle/123456789/32919 en application/pdf
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
language English
topic Underground electric cables
Fault location
spellingShingle Underground electric cables
Fault location
Mohd Satari Mohamad
Analysis of underground cable fault using time domain reflectometry technique
description TA169.6.M63 2017
format Resource Types::text::Final Year Project
author Mohd Satari Mohamad
author_facet Mohd Satari Mohamad
author_sort Mohd Satari Mohamad
title Analysis of underground cable fault using time domain reflectometry technique
title_short Analysis of underground cable fault using time domain reflectometry technique
title_full Analysis of underground cable fault using time domain reflectometry technique
title_fullStr Analysis of underground cable fault using time domain reflectometry technique
title_full_unstemmed Analysis of underground cable fault using time domain reflectometry technique
title_sort analysis of underground cable fault using time domain reflectometry technique
publishDate 2024
_version_ 1806428518860455936
score 13.222552