Failure analysis on a primary superheater tube of a power plant
In this paper failure analysis on the SA213-T12 superheater tube by visual inspection, in situ measurements of hardness and finite element analyses is presented. A primary superheater tube has failed with a wide open burst after running at around 28,194 h. Heavy clinkers were found to almost entirel...
Saved in:
Main Authors: | , , , , , |
---|---|
其他作者: | |
格式: | Article |
出版: |
2023
|
主题: | |
标签: |
添加标签
没有标签, 成为第一个标记此记录!
|