Simulation of existing gas-fuelled conventional steam power plant using Cycle Tempo

Simulation of a 200 MW gas-fuelled conventional steam power plant located in Basra, Iraq was carried out. The thermodynamic performance of the considered power plant is estimated by a system simulation. A flow-sheet computer program, �Cycle-Tempo� is used for the study. The plant components and pipi...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamel M.S., Rahman A.A., Shamsuddin A.H.
Other Authors: 55541995800
Format: Conference paper
Published: Institute of Physics Publishing 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Simulation of a 200 MW gas-fuelled conventional steam power plant located in Basra, Iraq was carried out. The thermodynamic performance of the considered power plant is estimated by a system simulation. A flow-sheet computer program, �Cycle-Tempo� is used for the study. The plant components and piping systems were considered and described in detail. The simulation results were verified against data gathered from the log sheet obtained from the station during its operation hours and good results were obtained. Operational factors like the stack exhaust temperature and excess air percentage were studied and discussed, as were environmental factors, such as ambient air temperature and water inlet temperature. In addition, detailed exergy losses were illustrated and describe the temperature profiles for the main plant components. The results prompted many suggestions for improvement of the plant performance. � Published under licence by IOP Publishing Ltd.