Investigation of bearing current in a gas turbine generator due to static excitation system

Shaft voltage and bearing current have become a serious problem in large power plants, the investigation of shaft voltage and bearing current in rotating machines have generated much attention in the field of electrical engineering. In this paper we present an investigation of bearing current phenom...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmed M.S., Mahdi H.F.
Other Authors: 57189239738
Format: Conference paper
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-30042
record_format dspace
spelling my.uniten.dspace-300422023-12-29T15:44:08Z Investigation of bearing current in a gas turbine generator due to static excitation system Ahmed M.S. Mahdi H.F. 57189239738 55029011500 Bearing current Breakdown voltage Electrical discharge machining (EDM) Shaft voltage Static excitation system Electric breakdown Electric discharge machining Electric discharges Gas turbines Power plants Static electricity Turbogenerators Bearing currents Electrical discharge machining Excitation winding Shaft voltage Shaft-bearing system Simulation model Static excitation Static excitation system Electric grounding Shaft voltage and bearing current have become a serious problem in large power plants, the investigation of shaft voltage and bearing current in rotating machines have generated much attention in the field of electrical engineering. In this paper we present an investigation of bearing current phenomena through the use of a simulation model of excitation winding and shaft-bearing system for a 96.3 MW gas turbine generator at a power plant. Simulation results obtained shows that bearing current is produced at the exciter end and turbine end of the generator due to the static excitation voltage. A solution to mitigate the bearing current by using grounding brushes is proposed. � 2013 IEEE. Final 2023-12-29T07:44:08Z 2023-12-29T07:44:08Z 2013 Conference paper 10.1109/SCOReD.2013.7002551 2-s2.0-84921768474 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84921768474&doi=10.1109%2fSCOReD.2013.7002551&partnerID=40&md5=14921e78caa57e60bd59364d1a307566 https://irepository.uniten.edu.my/handle/123456789/30042 7002551 100 104 All Open Access; Bronze Open Access Institute of Electrical and Electronics Engineers Inc. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Bearing current
Breakdown voltage
Electrical discharge machining (EDM)
Shaft voltage
Static excitation system
Electric breakdown
Electric discharge machining
Electric discharges
Gas turbines
Power plants
Static electricity
Turbogenerators
Bearing currents
Electrical discharge machining
Excitation winding
Shaft voltage
Shaft-bearing system
Simulation model
Static excitation
Static excitation system
Electric grounding
spellingShingle Bearing current
Breakdown voltage
Electrical discharge machining (EDM)
Shaft voltage
Static excitation system
Electric breakdown
Electric discharge machining
Electric discharges
Gas turbines
Power plants
Static electricity
Turbogenerators
Bearing currents
Electrical discharge machining
Excitation winding
Shaft voltage
Shaft-bearing system
Simulation model
Static excitation
Static excitation system
Electric grounding
Ahmed M.S.
Mahdi H.F.
Investigation of bearing current in a gas turbine generator due to static excitation system
description Shaft voltage and bearing current have become a serious problem in large power plants, the investigation of shaft voltage and bearing current in rotating machines have generated much attention in the field of electrical engineering. In this paper we present an investigation of bearing current phenomena through the use of a simulation model of excitation winding and shaft-bearing system for a 96.3 MW gas turbine generator at a power plant. Simulation results obtained shows that bearing current is produced at the exciter end and turbine end of the generator due to the static excitation voltage. A solution to mitigate the bearing current by using grounding brushes is proposed. � 2013 IEEE.
author2 57189239738
author_facet 57189239738
Ahmed M.S.
Mahdi H.F.
format Conference paper
author Ahmed M.S.
Mahdi H.F.
author_sort Ahmed M.S.
title Investigation of bearing current in a gas turbine generator due to static excitation system
title_short Investigation of bearing current in a gas turbine generator due to static excitation system
title_full Investigation of bearing current in a gas turbine generator due to static excitation system
title_fullStr Investigation of bearing current in a gas turbine generator due to static excitation system
title_full_unstemmed Investigation of bearing current in a gas turbine generator due to static excitation system
title_sort investigation of bearing current in a gas turbine generator due to static excitation system
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2023
_version_ 1806426083998826496
score 13.222552