Evaluation of magnetic field from different power transmission line configurations in malaysia
Double circuit overhead transmission lines in Malaysia have been in operation for many years. Rapid infrastructure development prompted the utility company to enhance electrical transmission capacity to ensure adequate and reliable supply to the consumers. Due to this some towers had been erected cl...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference paper |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-29905 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-299052023-12-28T16:58:09Z Evaluation of magnetic field from different power transmission line configurations in malaysia Said I. Rahman N.A. Hussain H. Farag A. Juhana T. 9336317400 9338388000 35607922800 57208098840 55241766100 EMF Health Effect Magnetic Field Reduction Transmission Lines Electric network analysis Electric power supplies to apparatus Electric towers Estimation Health care Magnetic field measurement EMF health effect Ground level magnetic field Magnetic field reduction Transmission line configuration Transmission line theory Double circuit overhead transmission lines in Malaysia have been in operation for many years. Rapid infrastructure development prompted the utility company to enhance electrical transmission capacity to ensure adequate and reliable supply to the consumers. Due to this some towers had been erected close to another tower. In certain places, under different circumstances it could consists of six towers energized within the same land reserve. It is estimated that 80% from the total number of transmission line towers in Malaysia are of the double circuit type while the rest are designed for the quadruple circuit type. There is a requirement to study and evaluate the impact of EMF exposure levels for these multiple towers. This paper presents the results of magnetic field measurements at various transmission line configurations in Malaysia. Using the actual physical dimensions of the transmission lines, models were constructed and verified. Simulation studies were then performed and ground level magnetic field at the edge of right-of-way and maximum magnetic field for each case was tabulated. The studies indicate that for the same number of circuits and carrying the same load, up to 47% of maximum magnetic field reduction can be achieved with a 33% reduction in the width of right-of way if the quadruple,circuit tower configuration is used. Final 2023-12-28T08:58:09Z 2023-12-28T08:58:09Z 2004 Conference paper 2-s2.0-4944248578 https://www.scopus.com/inward/record.uri?eid=2-s2.0-4944248578&partnerID=40&md5=89c9987e13f1b988577f37c2a1c6be97 https://irepository.uniten.edu.my/handle/123456789/29905 1 393 396 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
EMF Health Effect Magnetic Field Reduction Transmission Lines Electric network analysis Electric power supplies to apparatus Electric towers Estimation Health care Magnetic field measurement EMF health effect Ground level magnetic field Magnetic field reduction Transmission line configuration Transmission line theory |
spellingShingle |
EMF Health Effect Magnetic Field Reduction Transmission Lines Electric network analysis Electric power supplies to apparatus Electric towers Estimation Health care Magnetic field measurement EMF health effect Ground level magnetic field Magnetic field reduction Transmission line configuration Transmission line theory Said I. Rahman N.A. Hussain H. Farag A. Juhana T. Evaluation of magnetic field from different power transmission line configurations in malaysia |
description |
Double circuit overhead transmission lines in Malaysia have been in operation for many years. Rapid infrastructure development prompted the utility company to enhance electrical transmission capacity to ensure adequate and reliable supply to the consumers. Due to this some towers had been erected close to another tower. In certain places, under different circumstances it could consists of six towers energized within the same land reserve. It is estimated that 80% from the total number of transmission line towers in Malaysia are of the double circuit type while the rest are designed for the quadruple circuit type. There is a requirement to study and evaluate the impact of EMF exposure levels for these multiple towers. This paper presents the results of magnetic field measurements at various transmission line configurations in Malaysia. Using the actual physical dimensions of the transmission lines, models were constructed and verified. Simulation studies were then performed and ground level magnetic field at the edge of right-of-way and maximum magnetic field for each case was tabulated. The studies indicate that for the same number of circuits and carrying the same load, up to 47% of maximum magnetic field reduction can be achieved with a 33% reduction in the width of right-of way if the quadruple,circuit tower configuration is used. |
author2 |
9336317400 |
author_facet |
9336317400 Said I. Rahman N.A. Hussain H. Farag A. Juhana T. |
format |
Conference paper |
author |
Said I. Rahman N.A. Hussain H. Farag A. Juhana T. |
author_sort |
Said I. |
title |
Evaluation of magnetic field from different power transmission line configurations in malaysia |
title_short |
Evaluation of magnetic field from different power transmission line configurations in malaysia |
title_full |
Evaluation of magnetic field from different power transmission line configurations in malaysia |
title_fullStr |
Evaluation of magnetic field from different power transmission line configurations in malaysia |
title_full_unstemmed |
Evaluation of magnetic field from different power transmission line configurations in malaysia |
title_sort |
evaluation of magnetic field from different power transmission line configurations in malaysia |
publishDate |
2023 |
_version_ |
1806424182119989248 |
score |
13.222552 |