Evaluation of magnetic field from different power transmission line configurations in malaysia

Double circuit overhead transmission lines in Malaysia have been in operation for many years. Rapid infrastructure development prompted the utility company to enhance electrical transmission capacity to ensure adequate and reliable supply to the consumers. Due to this some towers had been erected cl...

Full description

Saved in:
Bibliographic Details
Main Authors: Said I., Rahman N.A., Hussain H., Farag A., Juhana T.
Other Authors: 9336317400
Format: Conference paper
Published: 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-29905
record_format dspace
spelling my.uniten.dspace-299052023-12-28T16:58:09Z Evaluation of magnetic field from different power transmission line configurations in malaysia Said I. Rahman N.A. Hussain H. Farag A. Juhana T. 9336317400 9338388000 35607922800 57208098840 55241766100 EMF Health Effect Magnetic Field Reduction Transmission Lines Electric network analysis Electric power supplies to apparatus Electric towers Estimation Health care Magnetic field measurement EMF health effect Ground level magnetic field Magnetic field reduction Transmission line configuration Transmission line theory Double circuit overhead transmission lines in Malaysia have been in operation for many years. Rapid infrastructure development prompted the utility company to enhance electrical transmission capacity to ensure adequate and reliable supply to the consumers. Due to this some towers had been erected close to another tower. In certain places, under different circumstances it could consists of six towers energized within the same land reserve. It is estimated that 80% from the total number of transmission line towers in Malaysia are of the double circuit type while the rest are designed for the quadruple circuit type. There is a requirement to study and evaluate the impact of EMF exposure levels for these multiple towers. This paper presents the results of magnetic field measurements at various transmission line configurations in Malaysia. Using the actual physical dimensions of the transmission lines, models were constructed and verified. Simulation studies were then performed and ground level magnetic field at the edge of right-of-way and maximum magnetic field for each case was tabulated. The studies indicate that for the same number of circuits and carrying the same load, up to 47% of maximum magnetic field reduction can be achieved with a 33% reduction in the width of right-of way if the quadruple,circuit tower configuration is used. Final 2023-12-28T08:58:09Z 2023-12-28T08:58:09Z 2004 Conference paper 2-s2.0-4944248578 https://www.scopus.com/inward/record.uri?eid=2-s2.0-4944248578&partnerID=40&md5=89c9987e13f1b988577f37c2a1c6be97 https://irepository.uniten.edu.my/handle/123456789/29905 1 393 396 Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic EMF Health Effect
Magnetic Field Reduction
Transmission Lines
Electric network analysis
Electric power supplies to apparatus
Electric towers
Estimation
Health care
Magnetic field measurement
EMF health effect
Ground level magnetic field
Magnetic field reduction
Transmission line configuration
Transmission line theory
spellingShingle EMF Health Effect
Magnetic Field Reduction
Transmission Lines
Electric network analysis
Electric power supplies to apparatus
Electric towers
Estimation
Health care
Magnetic field measurement
EMF health effect
Ground level magnetic field
Magnetic field reduction
Transmission line configuration
Transmission line theory
Said I.
Rahman N.A.
Hussain H.
Farag A.
Juhana T.
Evaluation of magnetic field from different power transmission line configurations in malaysia
description Double circuit overhead transmission lines in Malaysia have been in operation for many years. Rapid infrastructure development prompted the utility company to enhance electrical transmission capacity to ensure adequate and reliable supply to the consumers. Due to this some towers had been erected close to another tower. In certain places, under different circumstances it could consists of six towers energized within the same land reserve. It is estimated that 80% from the total number of transmission line towers in Malaysia are of the double circuit type while the rest are designed for the quadruple circuit type. There is a requirement to study and evaluate the impact of EMF exposure levels for these multiple towers. This paper presents the results of magnetic field measurements at various transmission line configurations in Malaysia. Using the actual physical dimensions of the transmission lines, models were constructed and verified. Simulation studies were then performed and ground level magnetic field at the edge of right-of-way and maximum magnetic field for each case was tabulated. The studies indicate that for the same number of circuits and carrying the same load, up to 47% of maximum magnetic field reduction can be achieved with a 33% reduction in the width of right-of way if the quadruple,circuit tower configuration is used.
author2 9336317400
author_facet 9336317400
Said I.
Rahman N.A.
Hussain H.
Farag A.
Juhana T.
format Conference paper
author Said I.
Rahman N.A.
Hussain H.
Farag A.
Juhana T.
author_sort Said I.
title Evaluation of magnetic field from different power transmission line configurations in malaysia
title_short Evaluation of magnetic field from different power transmission line configurations in malaysia
title_full Evaluation of magnetic field from different power transmission line configurations in malaysia
title_fullStr Evaluation of magnetic field from different power transmission line configurations in malaysia
title_full_unstemmed Evaluation of magnetic field from different power transmission line configurations in malaysia
title_sort evaluation of magnetic field from different power transmission line configurations in malaysia
publishDate 2023
_version_ 1806424182119989248
score 13.19449