Contamination of high voltage insulators in the east coast of Peninsular Malaysia

Rapid urbanization and industrialization in Malaysia over last two decades has resulted in increased demand for reliable electric power. The reliability in turn is greatly influenced by the grid system and its components being properly maintained. One of the important components is the high voltage...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmad A.S., Ahmad H., Jidin R.B., Tamsir T., Ahmed S.S., Buntat Z.
Other Authors: 7202040740
Format: Conference paper
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-29863
record_format dspace
spelling my.uniten.dspace-298632023-12-28T16:57:59Z Contamination of high voltage insulators in the east coast of Peninsular Malaysia Ahmad A.S. Ahmad H. Jidin R.B. Tamsir T. Ahmed S.S. Buntat Z. 7202040740 7102866725 6508169028 7801658692 57193735776 57194234727 Contamination ESDD High voltage Insulators Regression analysis Contamination Drought Electric insulators Regression analysis Salt deposits Equivalent salt deposit density ESDD High voltage High voltage insulators Hydrometeorological variables Multiple regression analysis Rapid urbanizations Reliable electric power Electric insulation Rapid urbanization and industrialization in Malaysia over last two decades has resulted in increased demand for reliable electric power. The reliability in turn is greatly influenced by the grid system and its components being properly maintained. One of the important components is the high voltage insulators used in the switchyards, overhead lines, substations and power stations. A common phenomenon in the east cost of Peninsular Malaysia is rapid buildup of salt contamination on high voltage insulators due to the salty wind coming from the South China Sea. The main objective of this paper is to develop a mathematical model correlating Equivalent Salt Deposit Density (ESDD) with the hydrometeorological variables. The data collected at one of the plants in the east coast during the dry season has been used to develop the model by using multiple regression analysis. This model has been validated for predicting contamination accumulation level during the dry season. � 2000 IEEE. Final 2023-12-28T08:57:59Z 2023-12-28T08:57:59Z 2000 Conference paper 10.1109/ICPST.2000.898144 2-s2.0-0005326257 https://www.scopus.com/inward/record.uri?eid=2-s2.0-0005326257&doi=10.1109%2fICPST.2000.898144&partnerID=40&md5=ea41a90e77d5eae1210eb11cd172c9ea https://irepository.uniten.edu.my/handle/123456789/29863 3 898144 1223 1228 Institute of Electrical and Electronics Engineers Inc. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
topic Contamination
ESDD
High voltage
Insulators
Regression analysis
Contamination
Drought
Electric insulators
Regression analysis
Salt deposits
Equivalent salt deposit density
ESDD
High voltage
High voltage insulators
Hydrometeorological variables
Multiple regression analysis
Rapid urbanizations
Reliable electric power
Electric insulation
spellingShingle Contamination
ESDD
High voltage
Insulators
Regression analysis
Contamination
Drought
Electric insulators
Regression analysis
Salt deposits
Equivalent salt deposit density
ESDD
High voltage
High voltage insulators
Hydrometeorological variables
Multiple regression analysis
Rapid urbanizations
Reliable electric power
Electric insulation
Ahmad A.S.
Ahmad H.
Jidin R.B.
Tamsir T.
Ahmed S.S.
Buntat Z.
Contamination of high voltage insulators in the east coast of Peninsular Malaysia
description Rapid urbanization and industrialization in Malaysia over last two decades has resulted in increased demand for reliable electric power. The reliability in turn is greatly influenced by the grid system and its components being properly maintained. One of the important components is the high voltage insulators used in the switchyards, overhead lines, substations and power stations. A common phenomenon in the east cost of Peninsular Malaysia is rapid buildup of salt contamination on high voltage insulators due to the salty wind coming from the South China Sea. The main objective of this paper is to develop a mathematical model correlating Equivalent Salt Deposit Density (ESDD) with the hydrometeorological variables. The data collected at one of the plants in the east coast during the dry season has been used to develop the model by using multiple regression analysis. This model has been validated for predicting contamination accumulation level during the dry season. � 2000 IEEE.
author2 7202040740
author_facet 7202040740
Ahmad A.S.
Ahmad H.
Jidin R.B.
Tamsir T.
Ahmed S.S.
Buntat Z.
format Conference paper
author Ahmad A.S.
Ahmad H.
Jidin R.B.
Tamsir T.
Ahmed S.S.
Buntat Z.
author_sort Ahmad A.S.
title Contamination of high voltage insulators in the east coast of Peninsular Malaysia
title_short Contamination of high voltage insulators in the east coast of Peninsular Malaysia
title_full Contamination of high voltage insulators in the east coast of Peninsular Malaysia
title_fullStr Contamination of high voltage insulators in the east coast of Peninsular Malaysia
title_full_unstemmed Contamination of high voltage insulators in the east coast of Peninsular Malaysia
title_sort contamination of high voltage insulators in the east coast of peninsular malaysia
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2023
_version_ 1806425805761282048
score 13.214268