Contamination of high voltage insulators in the east coast of Peninsular Malaysia
Rapid urbanization and industrialization in Malaysia over last two decades has resulted in increased demand for reliable electric power. The reliability in turn is greatly influenced by the grid system and its components being properly maintained. One of the important components is the high voltage...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Conference paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-29863 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-298632023-12-28T16:57:59Z Contamination of high voltage insulators in the east coast of Peninsular Malaysia Ahmad A.S. Ahmad H. Jidin R.B. Tamsir T. Ahmed S.S. Buntat Z. 7202040740 7102866725 6508169028 7801658692 57193735776 57194234727 Contamination ESDD High voltage Insulators Regression analysis Contamination Drought Electric insulators Regression analysis Salt deposits Equivalent salt deposit density ESDD High voltage High voltage insulators Hydrometeorological variables Multiple regression analysis Rapid urbanizations Reliable electric power Electric insulation Rapid urbanization and industrialization in Malaysia over last two decades has resulted in increased demand for reliable electric power. The reliability in turn is greatly influenced by the grid system and its components being properly maintained. One of the important components is the high voltage insulators used in the switchyards, overhead lines, substations and power stations. A common phenomenon in the east cost of Peninsular Malaysia is rapid buildup of salt contamination on high voltage insulators due to the salty wind coming from the South China Sea. The main objective of this paper is to develop a mathematical model correlating Equivalent Salt Deposit Density (ESDD) with the hydrometeorological variables. The data collected at one of the plants in the east coast during the dry season has been used to develop the model by using multiple regression analysis. This model has been validated for predicting contamination accumulation level during the dry season. � 2000 IEEE. Final 2023-12-28T08:57:59Z 2023-12-28T08:57:59Z 2000 Conference paper 10.1109/ICPST.2000.898144 2-s2.0-0005326257 https://www.scopus.com/inward/record.uri?eid=2-s2.0-0005326257&doi=10.1109%2fICPST.2000.898144&partnerID=40&md5=ea41a90e77d5eae1210eb11cd172c9ea https://irepository.uniten.edu.my/handle/123456789/29863 3 898144 1223 1228 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Contamination ESDD High voltage Insulators Regression analysis Contamination Drought Electric insulators Regression analysis Salt deposits Equivalent salt deposit density ESDD High voltage High voltage insulators Hydrometeorological variables Multiple regression analysis Rapid urbanizations Reliable electric power Electric insulation |
spellingShingle |
Contamination ESDD High voltage Insulators Regression analysis Contamination Drought Electric insulators Regression analysis Salt deposits Equivalent salt deposit density ESDD High voltage High voltage insulators Hydrometeorological variables Multiple regression analysis Rapid urbanizations Reliable electric power Electric insulation Ahmad A.S. Ahmad H. Jidin R.B. Tamsir T. Ahmed S.S. Buntat Z. Contamination of high voltage insulators in the east coast of Peninsular Malaysia |
description |
Rapid urbanization and industrialization in Malaysia over last two decades has resulted in increased demand for reliable electric power. The reliability in turn is greatly influenced by the grid system and its components being properly maintained. One of the important components is the high voltage insulators used in the switchyards, overhead lines, substations and power stations. A common phenomenon in the east cost of Peninsular Malaysia is rapid buildup of salt contamination on high voltage insulators due to the salty wind coming from the South China Sea. The main objective of this paper is to develop a mathematical model correlating Equivalent Salt Deposit Density (ESDD) with the hydrometeorological variables. The data collected at one of the plants in the east coast during the dry season has been used to develop the model by using multiple regression analysis. This model has been validated for predicting contamination accumulation level during the dry season. � 2000 IEEE. |
author2 |
7202040740 |
author_facet |
7202040740 Ahmad A.S. Ahmad H. Jidin R.B. Tamsir T. Ahmed S.S. Buntat Z. |
format |
Conference paper |
author |
Ahmad A.S. Ahmad H. Jidin R.B. Tamsir T. Ahmed S.S. Buntat Z. |
author_sort |
Ahmad A.S. |
title |
Contamination of high voltage insulators in the east coast of Peninsular Malaysia |
title_short |
Contamination of high voltage insulators in the east coast of Peninsular Malaysia |
title_full |
Contamination of high voltage insulators in the east coast of Peninsular Malaysia |
title_fullStr |
Contamination of high voltage insulators in the east coast of Peninsular Malaysia |
title_full_unstemmed |
Contamination of high voltage insulators in the east coast of Peninsular Malaysia |
title_sort |
contamination of high voltage insulators in the east coast of peninsular malaysia |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806425805761282048 |
score |
13.214268 |