Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector
A gas chromatography (GC) method has been developed to analyze simultaneously separate formulations of Diazinon, Malathion and Quinalphos with the internal standard method. A mixture of pure standard solution spiked with Chlorpyrifos as the internal standard and diluted with methanol was sonicated t...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2023
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-29783 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-297832023-12-28T16:57:39Z Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector Asha K.L. Tan G.H. Chai M.K. 16240801400 7202393048 24172523100 Diazinon GC-ECD Malathion Pesticide formulation Quinalphos A gas chromatography (GC) method has been developed to analyze simultaneously separate formulations of Diazinon, Malathion and Quinalphos with the internal standard method. A mixture of pure standard solution spiked with Chlorpyrifos as the internal standard and diluted with methanol was sonicated to homogenize the solutions. A 2?L volume of the mixture standard solution was injected into the GC-ECD and a six point calibration curve that demonstrated a linear range was established for each target compound. Samples of each formulation, mixed with the internal standard and diluted with methanol were injected into the GC-ECD. Combinations of three different concentrations of each formulated pesticide were analyzed six times to obtain coefficients of variation which are less than 1%. The total analysis time for each run was 15 minutes. The concentration of active ingredients in the pesticide formulations were calculated from the peak area values at a retention time interpolated from the calibration graphs. The analytical results which show 55.41 � 0.82% for Diazinon, 83.97 � 0.36% for Malathion and 10.89 � 0.89 % for Quinalphos were within the specifications for these commercial pesticide formulations. Final 2023-12-28T08:57:39Z 2023-12-28T08:57:39Z 2006 Article 2-s2.0-34247493701 https://www.scopus.com/inward/record.uri?eid=2-s2.0-34247493701&partnerID=40&md5=65b35f23804693faa59fd8bcbe358315 https://irepository.uniten.edu.my/handle/123456789/29783 25 2 131 138 Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
topic |
Diazinon GC-ECD Malathion Pesticide formulation Quinalphos |
spellingShingle |
Diazinon GC-ECD Malathion Pesticide formulation Quinalphos Asha K.L. Tan G.H. Chai M.K. Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector |
description |
A gas chromatography (GC) method has been developed to analyze simultaneously separate formulations of Diazinon, Malathion and Quinalphos with the internal standard method. A mixture of pure standard solution spiked with Chlorpyrifos as the internal standard and diluted with methanol was sonicated to homogenize the solutions. A 2?L volume of the mixture standard solution was injected into the GC-ECD and a six point calibration curve that demonstrated a linear range was established for each target compound. Samples of each formulation, mixed with the internal standard and diluted with methanol were injected into the GC-ECD. Combinations of three different concentrations of each formulated pesticide were analyzed six times to obtain coefficients of variation which are less than 1%. The total analysis time for each run was 15 minutes. The concentration of active ingredients in the pesticide formulations were calculated from the peak area values at a retention time interpolated from the calibration graphs. The analytical results which show 55.41 � 0.82% for Diazinon, 83.97 � 0.36% for Malathion and 10.89 � 0.89 % for Quinalphos were within the specifications for these commercial pesticide formulations. |
author2 |
16240801400 |
author_facet |
16240801400 Asha K.L. Tan G.H. Chai M.K. |
format |
Article |
author |
Asha K.L. Tan G.H. Chai M.K. |
author_sort |
Asha K.L. |
title |
Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector |
title_short |
Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector |
title_full |
Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector |
title_fullStr |
Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector |
title_full_unstemmed |
Simultaneous determination of Diazinon, Malathion and Quinalphos pesticide formulations by gas chromatography with an electron capture detector |
title_sort |
simultaneous determination of diazinon, malathion and quinalphos pesticide formulations by gas chromatography with an electron capture detector |
publishDate |
2023 |
_version_ |
1806426145131855872 |
score |
13.214268 |