Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor?

Housing; Lightning protection; Terminals (electric); Direct strike; Entertainment industry; Ground surfaces; Housing structure; Lightning safety; Potential gradients; Step potentials; Sturdy structures; Tourism industry; Working environment; Electric grounding

Saved in:
Bibliographic Details
Main Authors: Gomes C., Khurshid Z.M.
Other Authors: 57201335285
Format: Conference Paper
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-27053
record_format dspace
spelling my.uniten.dspace-270532023-05-29T17:39:04Z Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor? Gomes C. Khurshid Z.M. 57201335285 57199152644 Housing; Lightning protection; Terminals (electric); Direct strike; Entertainment industry; Ground surfaces; Housing structure; Lightning safety; Potential gradients; Step potentials; Sturdy structures; Tourism industry; Working environment; Electric grounding This study shows that in most cases of non-sturdy structures, protected with a grounded air terminal, the electric field inside the structure, is not much different from the case where the structure is not present. In order to have a significant difference in the electric field, the structure should be made of a material of which the conductivity is in the order of 0.001 S/m. The structural materials that are used in many applications have a much smaller conductivity. Such structures include housing for underprivileged communities, shelters in outdoor working environments, cabanas, tents, chalets and cottages etc. found in tourism, adventure, and entertainment industries. The potential gradient underneath the ground surface is also not altered noticeably when the area is enclosed by the covering structure. Thus, it is argued in this study that if the occupants inside such structures are protected by an isolated and grounded air terminal designed according to the IEC 62305 standards, the same could be applied to a person at an outdoor location. � 2022 IEEE. Final 2023-05-29T09:39:04Z 2023-05-29T09:39:04Z 2022 Conference Paper 10.1109/ICLP56858.2022.9942661 2-s2.0-85143063785 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85143063785&doi=10.1109%2fICLP56858.2022.9942661&partnerID=40&md5=70a19c070f30af97c984da3c7a729681 https://irepository.uniten.edu.my/handle/123456789/27053 730 733 Institute of Electrical and Electronics Engineers Inc. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Housing; Lightning protection; Terminals (electric); Direct strike; Entertainment industry; Ground surfaces; Housing structure; Lightning safety; Potential gradients; Step potentials; Sturdy structures; Tourism industry; Working environment; Electric grounding
author2 57201335285
author_facet 57201335285
Gomes C.
Khurshid Z.M.
format Conference Paper
author Gomes C.
Khurshid Z.M.
spellingShingle Gomes C.
Khurshid Z.M.
Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor?
author_sort Gomes C.
title Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor?
title_short Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor?
title_full Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor?
title_fullStr Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor?
title_full_unstemmed Lightning Safety with a Grounded Air-Terminal: Is there a Difference between Indoor and Outdoor?
title_sort lightning safety with a grounded air-terminal: is there a difference between indoor and outdoor?
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2023
_version_ 1806423239520419840
score 13.214268