Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1)

Introduction: Respirable Suspended Particulate (RSP) is a particularly serious indoor air pollution since at least a portion of particles ingested by humans can be permanently deposited in the respiratory tract. Analysis of indoor air quality in school classrooms is essential because the air quality...

Full description

Saved in:
Bibliographic Details
Main Authors: Mansor A.A., Ghazali M.I.H., Abdullah S., Dom N.C., Ahmed A.N., Ismail M.
Other Authors: 57211858557
Format: Article
Published: Universiti Putra Malaysia Press 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-26851
record_format dspace
spelling my.uniten.dspace-268512023-05-29T17:37:13Z Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1) Mansor A.A. Ghazali M.I.H. Abdullah S. Dom N.C. Ahmed A.N. Ismail M. 57211858557 57203210819 56509029800 57217286875 57214837520 57210403363 Introduction: Respirable Suspended Particulate (RSP) is a particularly serious indoor air pollution since at least a portion of particles ingested by humans can be permanently deposited in the respiratory tract. Analysis of indoor air quality in school classrooms is essential because the air quality can have a significant impact on the health and performance of children. Methods: The site selections were based on the surrounding activities of commercial and industrial areas. Instruments used for measuring parameters are Dust TraxTM DRX Aerosol II 8532 and Kanomax IAQ Monitor. Results: The study shows that the commercial area has a higher concentration of RSP compared to the industrial area. The I/O ratio value is higher at commercial area compared to industrial area with the value of PM10 = 3.065, PM2.5 = 3.222, PM1 = 3.261, CO2 =1.242, RH = 1.212, temperature = 0.891, and air movement = 1.072 for commercial area, and PM10 = 1.482, PM2.5 = 1.456, PM1 = 1.449, CO2 =1.116, RH = 1.134, temperature = 1.040, and air movement = 1.008 for the industrial area. For a commercial area, the indoor RSP is strongly correlated to all meteorological parameters with the value exceeding 0.5 except for CO2 has moderately correlated with the value is between 0.4 to 0.49, and wind speed has weak correlate with the value is less than 0.39 . Conclusion: : In conclusion, the classroom located in commercial is more polluted compared to the industrial area and the RSP is significantly influenced by meteorological factors. � 2022 UPM Press. All rights reserved. Final 2023-05-29T09:37:13Z 2023-05-29T09:37:13Z 2022 Article 10.47836/mjmhs18.8.22 2-s2.0-85134365310 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85134365310&doi=10.47836%2fmjmhs18.8.22&partnerID=40&md5=754d23fa252b669fa8dec10c1b1c409f https://irepository.uniten.edu.my/handle/123456789/26851 18 8 159 167 Universiti Putra Malaysia Press Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Introduction: Respirable Suspended Particulate (RSP) is a particularly serious indoor air pollution since at least a portion of particles ingested by humans can be permanently deposited in the respiratory tract. Analysis of indoor air quality in school classrooms is essential because the air quality can have a significant impact on the health and performance of children. Methods: The site selections were based on the surrounding activities of commercial and industrial areas. Instruments used for measuring parameters are Dust TraxTM DRX Aerosol II 8532 and Kanomax IAQ Monitor. Results: The study shows that the commercial area has a higher concentration of RSP compared to the industrial area. The I/O ratio value is higher at commercial area compared to industrial area with the value of PM10 = 3.065, PM2.5 = 3.222, PM1 = 3.261, CO2 =1.242, RH = 1.212, temperature = 0.891, and air movement = 1.072 for commercial area, and PM10 = 1.482, PM2.5 = 1.456, PM1 = 1.449, CO2 =1.116, RH = 1.134, temperature = 1.040, and air movement = 1.008 for the industrial area. For a commercial area, the indoor RSP is strongly correlated to all meteorological parameters with the value exceeding 0.5 except for CO2 has moderately correlated with the value is between 0.4 to 0.49, and wind speed has weak correlate with the value is less than 0.39 . Conclusion: : In conclusion, the classroom located in commercial is more polluted compared to the industrial area and the RSP is significantly influenced by meteorological factors. � 2022 UPM Press. All rights reserved.
author2 57211858557
author_facet 57211858557
Mansor A.A.
Ghazali M.I.H.
Abdullah S.
Dom N.C.
Ahmed A.N.
Ismail M.
format Article
author Mansor A.A.
Ghazali M.I.H.
Abdullah S.
Dom N.C.
Ahmed A.N.
Ismail M.
spellingShingle Mansor A.A.
Ghazali M.I.H.
Abdullah S.
Dom N.C.
Ahmed A.N.
Ismail M.
Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1)
author_sort Mansor A.A.
title Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1)
title_short Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1)
title_full Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1)
title_fullStr Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1)
title_full_unstemmed Investigating the Indoor and Outdoor Respirable Suspended Particulates of Coarse (PM10), Fine (PM2.5) and Ultrafine (PM1)
title_sort investigating the indoor and outdoor respirable suspended particulates of coarse (pm10), fine (pm2.5) and ultrafine (pm1)
publisher Universiti Putra Malaysia Press
publishDate 2023
_version_ 1806426663004667904
score 13.214268