Compromising the Data Integrity of an Electrical Power Grid SCADA System

Critical infrastructures; Electric power plants; Electric power transmission networks; Infrastructure as a service (IaaS); Manufacture; Network security; Patient monitoring; SCADA systems; Water supply; Control and monitoring; Electrical power generation; Man-In-The-Middle (MITM) Attack; Monitoring...

Full description

Saved in:
Bibliographic Details
Main Authors: Qassim Q.S., Jamil N., Daud M., Ja�affar N., Kamarulzaman W.A.W., Mahdi M.N.
Other Authors: 36613541700
Format: Conference Paper
Published: Springer Science and Business Media Deutschland GmbH 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-26571
record_format dspace
spelling my.uniten.dspace-265712023-05-29T17:12:09Z Compromising the Data Integrity of an Electrical Power Grid SCADA System Qassim Q.S. Jamil N. Daud M. Ja�affar N. Kamarulzaman W.A.W. Mahdi M.N. 36613541700 36682671900 57193904391 57204109050 6505975029 56727803900 Critical infrastructures; Electric power plants; Electric power transmission networks; Infrastructure as a service (IaaS); Manufacture; Network security; Patient monitoring; SCADA systems; Water supply; Control and monitoring; Electrical power generation; Man-In-The-Middle (MITM) Attack; Monitoring and controlling; National infrastructure; Production facility; Supervisory control and dataacquisition systems (SCADA); Transportation network; Electric power system control Supervisory Control and Data Acquisition (SCADA) systems perform monitoring and controlling services in critical national infrastructures such as electrical power generation and distribution, transportation networks, water supply and manufacturing, and production facilities. Cyber-attacks that compromise data integrity in SCADA systems such as an unauthorised manipulation of sensor or control signals could have a severe impact on the operation of the critical national infrastructure as it misleads system operators into making wrong decisions. This work investigates the man-in-the-middle (MITM) attack that aims explicitly at compromising data integrity of SCADA systems. The IEC 60870-5-104 tele-control communication protocol is used as the subject focus because it is a commonly used communication protocol in electrical power SCADA systems for tele-control and monitoring. We conducted several MITM attacks: covering the capturing, modification and injection of control commands, on IEC 60870-5-104 in our power grid SCADA system testbed. We described and performed the attacks in detail, together with several use cases. Based on the Proof-of-Concept (POC) conducted and data that we gathered, it shows that IEC 60870-5-104 is vulnerable against MITM attacks and it can be an entry point of cyberattacks, be it sophisticated or otherwise. � 2021, Springer Nature Singapore Pte Ltd. Final 2023-05-29T09:12:09Z 2023-05-29T09:12:09Z 2021 Conference Paper 10.1007/978-981-33-6835-4_40 2-s2.0-85101575520 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85101575520&doi=10.1007%2f978-981-33-6835-4_40&partnerID=40&md5=e017201117fc54fac28ef3234f19541a https://irepository.uniten.edu.my/handle/123456789/26571 1347 604 626 Springer Science and Business Media Deutschland GmbH Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Critical infrastructures; Electric power plants; Electric power transmission networks; Infrastructure as a service (IaaS); Manufacture; Network security; Patient monitoring; SCADA systems; Water supply; Control and monitoring; Electrical power generation; Man-In-The-Middle (MITM) Attack; Monitoring and controlling; National infrastructure; Production facility; Supervisory control and dataacquisition systems (SCADA); Transportation network; Electric power system control
author2 36613541700
author_facet 36613541700
Qassim Q.S.
Jamil N.
Daud M.
Ja�affar N.
Kamarulzaman W.A.W.
Mahdi M.N.
format Conference Paper
author Qassim Q.S.
Jamil N.
Daud M.
Ja�affar N.
Kamarulzaman W.A.W.
Mahdi M.N.
spellingShingle Qassim Q.S.
Jamil N.
Daud M.
Ja�affar N.
Kamarulzaman W.A.W.
Mahdi M.N.
Compromising the Data Integrity of an Electrical Power Grid SCADA System
author_sort Qassim Q.S.
title Compromising the Data Integrity of an Electrical Power Grid SCADA System
title_short Compromising the Data Integrity of an Electrical Power Grid SCADA System
title_full Compromising the Data Integrity of an Electrical Power Grid SCADA System
title_fullStr Compromising the Data Integrity of an Electrical Power Grid SCADA System
title_full_unstemmed Compromising the Data Integrity of an Electrical Power Grid SCADA System
title_sort compromising the data integrity of an electrical power grid scada system
publisher Springer Science and Business Media Deutschland GmbH
publishDate 2023
_version_ 1806423401215033344
score 13.214268