Compromising the Data Integrity of an Electrical Power Grid SCADA System
Critical infrastructures; Electric power plants; Electric power transmission networks; Infrastructure as a service (IaaS); Manufacture; Network security; Patient monitoring; SCADA systems; Water supply; Control and monitoring; Electrical power generation; Man-In-The-Middle (MITM) Attack; Monitoring...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Springer Science and Business Media Deutschland GmbH
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-26571 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-265712023-05-29T17:12:09Z Compromising the Data Integrity of an Electrical Power Grid SCADA System Qassim Q.S. Jamil N. Daud M. Ja�affar N. Kamarulzaman W.A.W. Mahdi M.N. 36613541700 36682671900 57193904391 57204109050 6505975029 56727803900 Critical infrastructures; Electric power plants; Electric power transmission networks; Infrastructure as a service (IaaS); Manufacture; Network security; Patient monitoring; SCADA systems; Water supply; Control and monitoring; Electrical power generation; Man-In-The-Middle (MITM) Attack; Monitoring and controlling; National infrastructure; Production facility; Supervisory control and dataacquisition systems (SCADA); Transportation network; Electric power system control Supervisory Control and Data Acquisition (SCADA) systems perform monitoring and controlling services in critical national infrastructures such as electrical power generation and distribution, transportation networks, water supply and manufacturing, and production facilities. Cyber-attacks that compromise data integrity in SCADA systems such as an unauthorised manipulation of sensor or control signals could have a severe impact on the operation of the critical national infrastructure as it misleads system operators into making wrong decisions. This work investigates the man-in-the-middle (MITM) attack that aims explicitly at compromising data integrity of SCADA systems. The IEC 60870-5-104 tele-control communication protocol is used as the subject focus because it is a commonly used communication protocol in electrical power SCADA systems for tele-control and monitoring. We conducted several MITM attacks: covering the capturing, modification and injection of control commands, on IEC 60870-5-104 in our power grid SCADA system testbed. We described and performed the attacks in detail, together with several use cases. Based on the Proof-of-Concept (POC) conducted and data that we gathered, it shows that IEC 60870-5-104 is vulnerable against MITM attacks and it can be an entry point of cyberattacks, be it sophisticated or otherwise. � 2021, Springer Nature Singapore Pte Ltd. Final 2023-05-29T09:12:09Z 2023-05-29T09:12:09Z 2021 Conference Paper 10.1007/978-981-33-6835-4_40 2-s2.0-85101575520 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85101575520&doi=10.1007%2f978-981-33-6835-4_40&partnerID=40&md5=e017201117fc54fac28ef3234f19541a https://irepository.uniten.edu.my/handle/123456789/26571 1347 604 626 Springer Science and Business Media Deutschland GmbH Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Critical infrastructures; Electric power plants; Electric power transmission networks; Infrastructure as a service (IaaS); Manufacture; Network security; Patient monitoring; SCADA systems; Water supply; Control and monitoring; Electrical power generation; Man-In-The-Middle (MITM) Attack; Monitoring and controlling; National infrastructure; Production facility; Supervisory control and dataacquisition systems (SCADA); Transportation network; Electric power system control |
author2 |
36613541700 |
author_facet |
36613541700 Qassim Q.S. Jamil N. Daud M. Ja�affar N. Kamarulzaman W.A.W. Mahdi M.N. |
format |
Conference Paper |
author |
Qassim Q.S. Jamil N. Daud M. Ja�affar N. Kamarulzaman W.A.W. Mahdi M.N. |
spellingShingle |
Qassim Q.S. Jamil N. Daud M. Ja�affar N. Kamarulzaman W.A.W. Mahdi M.N. Compromising the Data Integrity of an Electrical Power Grid SCADA System |
author_sort |
Qassim Q.S. |
title |
Compromising the Data Integrity of an Electrical Power Grid SCADA System |
title_short |
Compromising the Data Integrity of an Electrical Power Grid SCADA System |
title_full |
Compromising the Data Integrity of an Electrical Power Grid SCADA System |
title_fullStr |
Compromising the Data Integrity of an Electrical Power Grid SCADA System |
title_full_unstemmed |
Compromising the Data Integrity of an Electrical Power Grid SCADA System |
title_sort |
compromising the data integrity of an electrical power grid scada system |
publisher |
Springer Science and Business Media Deutschland GmbH |
publishDate |
2023 |
_version_ |
1806423401215033344 |
score |
13.214268 |