The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters
Electric resistance; Soils; Body of knowledge; Grounding grid design; Non-uniform soils; Protection systems; Safety assessments; Standards and guidelines; Substation grounding; Two layer soil model; Electric grounding
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-26568 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-265682023-05-29T17:12:06Z The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters Permal N. Osman M. Ariffin A.M. Ab Kadir M.Z.A. 56781496300 7201930315 16400722400 25947297000 Electric resistance; Soils; Body of knowledge; Grounding grid design; Non-uniform soils; Protection systems; Safety assessments; Standards and guidelines; Substation grounding; Two layer soil model; Electric grounding It is important to ensure that a grounding system is designed with a low magnitude of earth resistance, so the protection system can divert the large fault current to earth effectively. The performances and protection level of a grounding system need to be acknowledged as the condition of soil structure changes with different soil characteristics. At present, there is a lack of systematic guide or standards for grounding grid designs that consider non-uniform soil and its impact on the grounding systems. By computing the grid safety threshold parameters consisting of the grid impedance, step, and touch voltages, a comparison has been made between uniform soil and two-layer soil models. Where the competence and level of safety of the grounding systems depend on the soil attributes, the significant impact of various soil conditions is seen. The evaluations on performance and safety assessment in two-layer soil conditions hold the novelty and originality as there is no such comparison and discussion have been made to date. These comparisons would help in forecasting the behavior and safety of the grounding system in various soil environments, which would provide engineers with additional expertise to design an effective and secure grounding system. This research would contribute to the existing body of knowledge by differentiating and predicting the performance of a grounding system when the characteristics of the soil differ significantly from uniform soil as most of the standards and guidelines only consider uniform soil while designing a grounding system, owing to its complexity at the site. � 2020 Institute of Electrical and Electronics Engineers Inc.. All rights reserved. Final 2023-05-29T09:12:06Z 2023-05-29T09:12:06Z 2021 Article 10.1109/ACCESS.2021.3063018 2-s2.0-85102251041 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85102251041&doi=10.1109%2fACCESS.2021.3063018&partnerID=40&md5=c28d14d17679156e3e3fa2f20af51725 https://irepository.uniten.edu.my/handle/123456789/26568 9 37497 37509 All Open Access, Gold, Green Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Electric resistance; Soils; Body of knowledge; Grounding grid design; Non-uniform soils; Protection systems; Safety assessments; Standards and guidelines; Substation grounding; Two layer soil model; Electric grounding |
author2 |
56781496300 |
author_facet |
56781496300 Permal N. Osman M. Ariffin A.M. Ab Kadir M.Z.A. |
format |
Article |
author |
Permal N. Osman M. Ariffin A.M. Ab Kadir M.Z.A. |
spellingShingle |
Permal N. Osman M. Ariffin A.M. Ab Kadir M.Z.A. The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters |
author_sort |
Permal N. |
title |
The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters |
title_short |
The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters |
title_full |
The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters |
title_fullStr |
The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters |
title_full_unstemmed |
The impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters |
title_sort |
impact of substation grounding grid design parameters in non-homogenous soil to the grid safety threshold parameters |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806424350769807360 |
score |
13.222552 |