Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System

Electric grounding; Electric resistance; Lightning protection; Surge protection; AC-side; CENELEC standards; DC side; Earth resistance; Earthing system; Grid connected PV system; Grounding resistance; PV system; Surge protective device; Surge protective devices; Transient analysis

Saved in:
Bibliographic Details
Main Authors: Khurshid Z.M., Gomes C.
Other Authors: 57199152644
Format: Conference Paper
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-26401
record_format dspace
spelling my.uniten.dspace-264012023-05-29T17:10:01Z Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System Khurshid Z.M. Gomes C. 57199152644 57201335285 Electric grounding; Electric resistance; Lightning protection; Surge protection; AC-side; CENELEC standards; DC side; Earth resistance; Earthing system; Grid connected PV system; Grounding resistance; PV system; Surge protective device; Surge protective devices; Transient analysis This paper investigates the potential and current distribution of a grid-connected (PV) system with surge protective devices connected according to the European Commission for Electrotechnical Standardization (CENELEC) under various values of grounding resistance for isolated and integrated AC and DC earthing systems. A 400 kW PV system is implemented using PSCAD/EMTDC software, where the system is connected to a 33 kV grid through a boost transformer. The simulation results were obtained for negative subsequent lightning stroke (50% value), developed by Heidler function. The current was injected separately into both the DC and the AC sides of the PV inverter. The values of resistance of the earthing systems have been varied over a set of combinations. The results show that when the AC and DC sides are separately earthed for non-zero values of resistance, the line potentials reach very high values posing a severe risk of a system to earth arcing. The situation is worse when the lightning strikes the DC side and when the DC side earth resistance has high values. The situation improves significantly when the earthing systems are integrated. It is advisable to achieve an earth resistance below 5 ? for the integrated earthing system. � 2021 IEEE. Final 2023-05-29T09:10:01Z 2023-05-29T09:10:01Z 2021 Conference Paper 10.1109/ICLPandSIPDA54065.2021.9627347 2-s2.0-85123856749 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85123856749&doi=10.1109%2fICLPandSIPDA54065.2021.9627347&partnerID=40&md5=be5a1248b485e2d90fdb06c84bee77ce https://irepository.uniten.edu.my/handle/123456789/26401 Institute of Electrical and Electronics Engineers Inc. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Electric grounding; Electric resistance; Lightning protection; Surge protection; AC-side; CENELEC standards; DC side; Earth resistance; Earthing system; Grid connected PV system; Grounding resistance; PV system; Surge protective device; Surge protective devices; Transient analysis
author2 57199152644
author_facet 57199152644
Khurshid Z.M.
Gomes C.
format Conference Paper
author Khurshid Z.M.
Gomes C.
spellingShingle Khurshid Z.M.
Gomes C.
Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System
author_sort Khurshid Z.M.
title Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System
title_short Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System
title_full Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System
title_fullStr Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System
title_full_unstemmed Impacts of Earthing Arrangement on Lightning Protection Efficiency of Grid Connected PV System
title_sort impacts of earthing arrangement on lightning protection efficiency of grid connected pv system
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2023
_version_ 1806427865177128960
score 13.211869