Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system
This paper discusses the lightning-induced voltage effect on a hybrid solar photovoltaic (PV)-battery energy storage system with the presence of surge protection devices (SPD). Solar PV functions by utilizing solar energy, in generating electricity, to supply to the customer. To ensure its consisten...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
MDPI AG
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-26154 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-261542023-05-29T17:07:15Z Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system Ahmad N.I. Ali Z. Kadir M.Z.A.A. Osman M. Zaini N.H. Roslan M.H. 56405049800 25824589000 25947297000 7201930315 55865700900 56405424900 This paper discusses the lightning-induced voltage effect on a hybrid solar photovoltaic (PV)-battery energy storage system with the presence of surge protection devices (SPD). Solar PV functions by utilizing solar energy, in generating electricity, to supply to the customer. To ensure its consistency, battery energy storage is introduced to cater to the energy demand. For the countries located at the Equator, lightning has always become a major issue for the system to operate at maximum efficiency, due to its nature of installation in open space areas where the equipment may suffer serious damage that may stop the operation abruptly. To minimize the possible damages, insulation coordination on the lightning protection system is needed. Hence, three case studies, i.e., lightning current amplitude, lightning strike distance, and cable length are presented in this paper, which the quantified analysis is taking into account, to identify the performance of the system with the single installation of SPD Class II at DC and AC sides. The simulation results have contributed towards a better understanding of the importance of SPDs, and the need to properly coordinate according to the standard, taking into account the quantified information obtained from this work, hence providing the necessity of proper installation of SPD will provide better maintenance and prolong the lifespan of the equipment. � 2021 by the authors. Licensee MDPI, Basel, Switzerland. Final 2023-05-29T09:07:15Z 2023-05-29T09:07:15Z 2021 Article 10.3390/su13126889 2-s2.0-85108687081 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108687081&doi=10.3390%2fsu13126889&partnerID=40&md5=ccc0357bee3a9a6136a3fcc8ee7b617c https://irepository.uniten.edu.my/handle/123456789/26154 13 12 6889 All Open Access, Gold, Green MDPI AG Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
This paper discusses the lightning-induced voltage effect on a hybrid solar photovoltaic (PV)-battery energy storage system with the presence of surge protection devices (SPD). Solar PV functions by utilizing solar energy, in generating electricity, to supply to the customer. To ensure its consistency, battery energy storage is introduced to cater to the energy demand. For the countries located at the Equator, lightning has always become a major issue for the system to operate at maximum efficiency, due to its nature of installation in open space areas where the equipment may suffer serious damage that may stop the operation abruptly. To minimize the possible damages, insulation coordination on the lightning protection system is needed. Hence, three case studies, i.e., lightning current amplitude, lightning strike distance, and cable length are presented in this paper, which the quantified analysis is taking into account, to identify the performance of the system with the single installation of SPD Class II at DC and AC sides. The simulation results have contributed towards a better understanding of the importance of SPDs, and the need to properly coordinate according to the standard, taking into account the quantified information obtained from this work, hence providing the necessity of proper installation of SPD will provide better maintenance and prolong the lifespan of the equipment. � 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
author2 |
56405049800 |
author_facet |
56405049800 Ahmad N.I. Ali Z. Kadir M.Z.A.A. Osman M. Zaini N.H. Roslan M.H. |
format |
Article |
author |
Ahmad N.I. Ali Z. Kadir M.Z.A.A. Osman M. Zaini N.H. Roslan M.H. |
spellingShingle |
Ahmad N.I. Ali Z. Kadir M.Z.A.A. Osman M. Zaini N.H. Roslan M.H. Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system |
author_sort |
Ahmad N.I. |
title |
Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system |
title_short |
Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system |
title_full |
Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system |
title_fullStr |
Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system |
title_full_unstemmed |
Analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system |
title_sort |
analysis of lightning-induced voltages effect with spd placement for sustainable operation in hybrid solar pv-battery energy storage system |
publisher |
MDPI AG |
publishDate |
2023 |
_version_ |
1806426112723517440 |
score |
13.214268 |