Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way
Cable sheathing; Dielectric materials; Electric grounding; Electric lines; Electromagnetic pulse; Rights of way; Telecommunication cables; Current distribution; International standards; Mitigation techniques; Overhead transmission lines; Simulation and analysis; Soil-structure analysis; Steady-state...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-26095 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-260952023-05-29T17:06:45Z Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way Harun Z.A. Osman M. Ariffin A.M. Zainal Abidin Ab Kadir M. 57226576605 7201930315 16400722400 25947297000 Cable sheathing; Dielectric materials; Electric grounding; Electric lines; Electromagnetic pulse; Rights of way; Telecommunication cables; Current distribution; International standards; Mitigation techniques; Overhead transmission lines; Simulation and analysis; Soil-structure analysis; Steady-state operation; Transportation infrastructures; Underground cables Issues and interest of AC interference from Overhead Transmission Lines (OHTL) to nearby co-located facilities not only involve pipelines, communication cables and transportation infrastructures but also to nearby High Voltage (HV) underground cables. In this paper, the effects on a three phase AC 275kV underground cable running in parallel to three phase AC double circuit of 275kV OHTL are studied using Current Distribution, Electromagnetic Interference, Grounding and Soil Structure Analysis (CDEGS) software program. The underground cable under study is placed within the OHTL Right of Way (ROW) where the modelling, simulation and analysis of both systems are presented in order to assess induced voltage on the sheath of an underground cable. This paper investigates the case when OHTL and underground cable were energized during steady state operation with respect to different length and parallelism of both systems. During the operation of both systems, induced sheath voltage on the cables has increased and voltage distribution changed significantly which can stress the sheath itself. The induced voltage on underground cable sheath has been reduced to tolerable sheath standing voltage as specified by international standard by proposing some mitigation techniques. � 2021 IEEE. Final 2023-05-29T09:06:45Z 2023-05-29T09:06:45Z 2021 Conference Paper 10.1109/ICPADM49635.2021.9493894 2-s2.0-85112011507 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85112011507&doi=10.1109%2fICPADM49635.2021.9493894&partnerID=40&md5=6f4d19847fb87c7539c9b7abd764590f https://irepository.uniten.edu.my/handle/123456789/26095 2021-July 9493894 73 76 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Cable sheathing; Dielectric materials; Electric grounding; Electric lines; Electromagnetic pulse; Rights of way; Telecommunication cables; Current distribution; International standards; Mitigation techniques; Overhead transmission lines; Simulation and analysis; Soil-structure analysis; Steady-state operation; Transportation infrastructures; Underground cables |
author2 |
57226576605 |
author_facet |
57226576605 Harun Z.A. Osman M. Ariffin A.M. Zainal Abidin Ab Kadir M. |
format |
Conference Paper |
author |
Harun Z.A. Osman M. Ariffin A.M. Zainal Abidin Ab Kadir M. |
spellingShingle |
Harun Z.A. Osman M. Ariffin A.M. Zainal Abidin Ab Kadir M. Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way |
author_sort |
Harun Z.A. |
title |
Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way |
title_short |
Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way |
title_full |
Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way |
title_fullStr |
Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way |
title_full_unstemmed |
Effect of AC Interference on HV Underground Cables Buried within Transmission Lines Right of Way |
title_sort |
effect of ac interference on hv underground cables buried within transmission lines right of way |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806423248639885312 |
score |
13.214268 |