Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data

This paper presents a novel approach for predicting the remaining life of lattice steel transmission towers in Malaysia. The transmission tower components assessment grouped into ground corrosive condition, foundation condition, lattice steel body of the tower, and conductor. Significant and scienti...

Full description

Saved in:
Bibliographic Details
Main Authors: Usman F., Khalid N.H.N.
Other Authors: 55812540000
Format: Conference Paper
Published: EDP Sciences 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-25899
record_format dspace
spelling my.uniten.dspace-258992023-05-29T17:05:28Z Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data Usman F. Khalid N.H.N. 55812540000 58077885700 This paper presents a novel approach for predicting the remaining life of lattice steel transmission towers in Malaysia. The transmission tower components assessment grouped into ground corrosive condition, foundation condition, lattice steel body of the tower, and conductor. Significant and scientific field investigation and visual assessment evaluate the state of the tower. The corrosion hazard, which is a product of climate and air pollution data, is used. Three separated lines and 84 towers were selected with different ages of the tower in service. The Weighing Scoring Method with Analytical Hierarchy Process to impose the weighed factor was used. The survival function analysis is used to predict service life, and the tower remaining life was determined. The paper shows how to use the model to predict the remaining life of a transmission tower and how this can be used to advise maintenance planning. � The Authors, published by EDP Sciences. Final 2023-05-29T09:05:28Z 2023-05-29T09:05:28Z 2021 Conference Paper 10.1051/e3sconf/202132501011 2-s2.0-85146777319 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146777319&doi=10.1051%2fe3sconf%2f202132501011&partnerID=40&md5=977377812c59196b7e044a999efaaafd https://irepository.uniten.edu.my/handle/123456789/25899 325 1011 All Open Access, Gold, Green EDP Sciences Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description This paper presents a novel approach for predicting the remaining life of lattice steel transmission towers in Malaysia. The transmission tower components assessment grouped into ground corrosive condition, foundation condition, lattice steel body of the tower, and conductor. Significant and scientific field investigation and visual assessment evaluate the state of the tower. The corrosion hazard, which is a product of climate and air pollution data, is used. Three separated lines and 84 towers were selected with different ages of the tower in service. The Weighing Scoring Method with Analytical Hierarchy Process to impose the weighed factor was used. The survival function analysis is used to predict service life, and the tower remaining life was determined. The paper shows how to use the model to predict the remaining life of a transmission tower and how this can be used to advise maintenance planning. � The Authors, published by EDP Sciences.
author2 55812540000
author_facet 55812540000
Usman F.
Khalid N.H.N.
format Conference Paper
author Usman F.
Khalid N.H.N.
spellingShingle Usman F.
Khalid N.H.N.
Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data
author_sort Usman F.
title Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data
title_short Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data
title_full Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data
title_fullStr Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data
title_full_unstemmed Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data
title_sort predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data
publisher EDP Sciences
publishDate 2023
_version_ 1806427394970484736
score 13.222552