Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System
Computational fluid dynamics; Housing; Thermal comfort; Active cooling; Hybrid ventilation system; Indoor thermal comfort; Mechanical ventilation; Mechanical ventilation system; Natural ventilation; PMV, PPD; Residential house; Ventilation
Saved in:
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Book Chapter |
Published: |
Springer
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-25792 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-257922023-05-29T16:14:21Z Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System Usman F. Bakar A.R.A. 55812540000 57213146825 Computational fluid dynamics; Housing; Thermal comfort; Active cooling; Hybrid ventilation system; Indoor thermal comfort; Mechanical ventilation; Mechanical ventilation system; Natural ventilation; PMV, PPD; Residential house; Ventilation Combination of natural and mechanical ventilation is defined as a hybrid ventilation system. This system has drawn attention in indoor thermal comfort. This paper presents a CFD analysis for thermal comfort study of a residential house model. Different scenarios given to the model to evaluate the effect of the mechanical ventilation system of ceiling fan assisted the air flow and natural ventilation in indoor thermal comfort. Predictive Mean Vote (PMV) as in ASHRAE 55 and the thermal comfort (Tc) as suggested in MS 2680:2017 were calculated. From the study, it is found that there is an improvement value of PMV value by +0.1 to +0.2 by having ceiling fans as indoor assisted airflow. � Springer Nature Switzerland AG 2020. Final 2023-05-29T08:14:21Z 2023-05-29T08:14:21Z 2020 Book Chapter 10.1007/978-3-030-32816-0_124 2-s2.0-85077578638 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85077578638&doi=10.1007%2f978-3-030-32816-0_124&partnerID=40&md5=fafe2d11a1aa1780b5d04b40077940be https://irepository.uniten.edu.my/handle/123456789/25792 53 1613 1628 Springer Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Computational fluid dynamics; Housing; Thermal comfort; Active cooling; Hybrid ventilation system; Indoor thermal comfort; Mechanical ventilation; Mechanical ventilation system; Natural ventilation; PMV, PPD; Residential house; Ventilation |
author2 |
55812540000 |
author_facet |
55812540000 Usman F. Bakar A.R.A. |
format |
Book Chapter |
author |
Usman F. Bakar A.R.A. |
spellingShingle |
Usman F. Bakar A.R.A. Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System |
author_sort |
Usman F. |
title |
Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System |
title_short |
Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System |
title_full |
Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System |
title_fullStr |
Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System |
title_full_unstemmed |
Thermal Comfort Study Using CFD Analysis in Residential House with Mechanical Ventilation System |
title_sort |
thermal comfort study using cfd analysis in residential house with mechanical ventilation system |
publisher |
Springer |
publishDate |
2023 |
_version_ |
1806425829322784768 |
score |
13.214268 |