Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength
Electric transformer testing; Infrared devices; Mean square error; Near infrared spectroscopy; Power transformers; Voltage measurement; Conventional techniques; Inhibitor concentration; New mathematical model; Optical measuring devices; Performance comparison; Prototype verification; Root mean squar...
Saved in:
Main Authors: | , , , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-25198 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-251982023-05-29T16:07:17Z Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength Leong Y.S. Jern Ker P. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. 57202929965 57222032755 57207576846 57204588662 7103014445 57216839721 6507460925 Electric transformer testing; Infrared devices; Mean square error; Near infrared spectroscopy; Power transformers; Voltage measurement; Conventional techniques; Inhibitor concentration; New mathematical model; Optical measuring devices; Performance comparison; Prototype verification; Root mean square errors; Transformer oil samples; Oil filled transformers Monitoring the insulation system of power transformers is crucial in ensuring power transformers are operating in optimal conditions. Due to the non-direct and destructive nature of conventional techniques, optical techniques have prevailed to be an effective alternative to monitor the condition of the insulation system. The recent development of small and compact optical components has also contributed to the utilization of optical techniques in on-site testing and on-line monitoring application. Therefore, this work proposed the measurement of inhibitor concentration in transformer oil using a portable optical measuring device that utilizes near-infrared spectroscopy. The fundamental studies of measuring inhibitor in transformer oil using a newly discovered wavelength at 1403nm were validated and its adaptation to a portable optical measuring device was discussed. A new mathematical model was formulated to estimate the inhibitor concentration in transformer oil samples based on the data obtained from the photodetector. The measurements were then conducted along with the conventional technique for performance comparison and prototype verification. The results showed a root-mean-square-error of 0.01708 and an average error of 2.11%. This proposed prototype opens up opportunities in on-site testing and on-line monitoring of inhibitor content concentration in transformer oil. � 2020 IEEE. Final 2023-05-29T08:07:17Z 2023-05-29T08:07:17Z 2020 Conference Paper 10.1109/IAS44978.2020.9334762 2-s2.0-85100976987 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100976987&doi=10.1109%2fIAS44978.2020.9334762&partnerID=40&md5=e4a32738b1a570a417cfd819c20d8610 https://irepository.uniten.edu.my/handle/123456789/25198 9334762 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Electric transformer testing; Infrared devices; Mean square error; Near infrared spectroscopy; Power transformers; Voltage measurement; Conventional techniques; Inhibitor concentration; New mathematical model; Optical measuring devices; Performance comparison; Prototype verification; Root mean square errors; Transformer oil samples; Oil filled transformers |
author2 |
57202929965 |
author_facet |
57202929965 Leong Y.S. Jern Ker P. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. |
format |
Conference Paper |
author |
Leong Y.S. Jern Ker P. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. |
spellingShingle |
Leong Y.S. Jern Ker P. Hasnul M.H. Khamis M.A. Hannan M.A. Jamaludin M.Z. Looe H.M. Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength |
author_sort |
Leong Y.S. |
title |
Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength |
title_short |
Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength |
title_full |
Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength |
title_fullStr |
Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength |
title_full_unstemmed |
Portable Device for Transformer Oil Inhibitor Content Analysis Using Near-Infrared Spectroscopy Wavelength |
title_sort |
portable device for transformer oil inhibitor content analysis using near-infrared spectroscopy wavelength |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806424175890399232 |
score |
13.214268 |