Analysis of geomagnetic induced current modelling and calculation in electrical power grid
Electric grounding; Geomagnetism; Intercalation; Earth magnetic fields; Electrical power; Geomagnetic disturbance; Geomagnetic induced currents; Geomagnetic storm; In-Degree; Nodal analysis method; Voltage collapse; Electric power transmission networks
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-25075 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-250752023-05-29T16:06:40Z Analysis of geomagnetic induced current modelling and calculation in electrical power grid Amran A.S. Ab Aziz N.F. Zawawi A.A. Yasin Z.M. Salim N.A. 57221909012 57221906825 57219849903 57211410254 36806685300 Electric grounding; Geomagnetism; Intercalation; Earth magnetic fields; Electrical power; Geomagnetic disturbance; Geomagnetic induced currents; Geomagnetic storm; In-Degree; Nodal analysis method; Voltage collapse; Electric power transmission networks Geomagnetic induced current (GIC) caused by geomagnetic disturbance (GMD) can be a serious threat to a stable electrical power grid operation. GIC that is induced in the earth magnetic field flows through the neutrals of grounded-wye transformers may lead to increasing reactive power consumption which can result to voltage collapse. Therefore, it is important to study the evaluation of this event on the electrical power grid. This paper presents the analysis of GIC modelling and calculation in a 4 bus test case system using Power World Simulator. The value of calculated GIC using Power World are validated and compared with theoretical using nodal analysis method. Based on the study conducted, it is found that the geomagnetic storm magnitude and direction in degrees can affect the GIC values. � 2020 IEEE. Final 2023-05-29T08:06:40Z 2023-05-29T08:06:40Z 2020 Conference Paper 10.1109/PECon48942.2020.9314477 2-s2.0-85100598807 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85100598807&doi=10.1109%2fPECon48942.2020.9314477&partnerID=40&md5=cf20bc1c160cb9828084e954dc22147e https://irepository.uniten.edu.my/handle/123456789/25075 9314477 194 197 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Electric grounding; Geomagnetism; Intercalation; Earth magnetic fields; Electrical power; Geomagnetic disturbance; Geomagnetic induced currents; Geomagnetic storm; In-Degree; Nodal analysis method; Voltage collapse; Electric power transmission networks |
author2 |
57221909012 |
author_facet |
57221909012 Amran A.S. Ab Aziz N.F. Zawawi A.A. Yasin Z.M. Salim N.A. |
format |
Conference Paper |
author |
Amran A.S. Ab Aziz N.F. Zawawi A.A. Yasin Z.M. Salim N.A. |
spellingShingle |
Amran A.S. Ab Aziz N.F. Zawawi A.A. Yasin Z.M. Salim N.A. Analysis of geomagnetic induced current modelling and calculation in electrical power grid |
author_sort |
Amran A.S. |
title |
Analysis of geomagnetic induced current modelling and calculation in electrical power grid |
title_short |
Analysis of geomagnetic induced current modelling and calculation in electrical power grid |
title_full |
Analysis of geomagnetic induced current modelling and calculation in electrical power grid |
title_fullStr |
Analysis of geomagnetic induced current modelling and calculation in electrical power grid |
title_full_unstemmed |
Analysis of geomagnetic induced current modelling and calculation in electrical power grid |
title_sort |
analysis of geomagnetic induced current modelling and calculation in electrical power grid |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806428077560954880 |
score |
13.222552 |