High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System
Computer software; Electric impedance measurement; Telecommunication cables; Testing; Underground cables; Distribution cables; Experimental values; High frequency alternating current; Higher frequencies; In-service failures; Insulation conditions; Measurement techniques; Underground power cable syst...
Saved in:
Main Authors: | , , , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-24783 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-247832023-05-29T15:27:00Z High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System Ghani A.B.A. Chakrabarty C.K. Ramasamy A.K. Avinash A.R. Shafie H. Permal N. Danikas M.G. 24469638000 6701755282 16023154400 56781356900 57207853865 56781496300 7003752405 Computer software; Electric impedance measurement; Telecommunication cables; Testing; Underground cables; Distribution cables; Experimental values; High frequency alternating current; Higher frequencies; In-service failures; Insulation conditions; Measurement techniques; Underground power cable system; Cable sheathing The aim of this paper is to show that Tan delta HFAC technique is applicable for longer cables. As underground cables are in service for years, it is necessary to carry out diagnostic test to rectify the possible problem that may occur in a cable so that precautionary action can be taken to avoid unnecessary in-service failure of the cable. One of the diagnostic testing techniques, known as Tangent Delta, is a method of testing cables to define the insulation condition of the underground cable. The phase shifts caused by the lossy current due to the existence of impurities in cable insulation is measured in this method. As most of distribution cables are long lengths, it becomes necessary to measure the tangent delta for these longer cables. In this paper, HFAC technique on longer length of good condition 11 KV power cables were used as samples to determine the tangent delta. Higher frequencies ( >100 Hz) were used to determine the tangent delta of cables at voltage of 1kV. The current (I) and phase theta were obtained in this experiment using HFAC measurement technique. CST Cable Suite software was used for simulating the experiment to verify the HFAC experimental setup by attaining sufficient dielectric current obtained through simulation and compare the leakage current values with the experimental values. The tangent delta results were attained for good cable with the length of 40 m, 70 m and 140 m and compared with 20 m length of good condition cable. The tangent delta results show that the HFAC technique is also applicable for the longer cable as well. � 2018 IEEE. Final 2023-05-29T07:26:59Z 2023-05-29T07:26:59Z 2019 Conference Paper 10.1109/ICHVE.2018.8641840 2-s2.0-85063084950 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85063084950&doi=10.1109%2fICHVE.2018.8641840&partnerID=40&md5=f5c4fa94a21b23c32e31ade7dbdf5bbc https://irepository.uniten.edu.my/handle/123456789/24783 8641840 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Computer software; Electric impedance measurement; Telecommunication cables; Testing; Underground cables; Distribution cables; Experimental values; High frequency alternating current; Higher frequencies; In-service failures; Insulation conditions; Measurement techniques; Underground power cable system; Cable sheathing |
author2 |
24469638000 |
author_facet |
24469638000 Ghani A.B.A. Chakrabarty C.K. Ramasamy A.K. Avinash A.R. Shafie H. Permal N. Danikas M.G. |
format |
Conference Paper |
author |
Ghani A.B.A. Chakrabarty C.K. Ramasamy A.K. Avinash A.R. Shafie H. Permal N. Danikas M.G. |
spellingShingle |
Ghani A.B.A. Chakrabarty C.K. Ramasamy A.K. Avinash A.R. Shafie H. Permal N. Danikas M.G. High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System |
author_sort |
Ghani A.B.A. |
title |
High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System |
title_short |
High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System |
title_full |
High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System |
title_fullStr |
High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System |
title_full_unstemmed |
High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System |
title_sort |
high frequency alternating current (ac) tangent delta measurement technique for underground power cable system |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806426300427010048 |
score |
13.214268 |