Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm
Electric insulation; Electric power transmission; Flashover; Towers; ANSYS Maxwell; Electric field profiles; Feasibility studies; Lightning activity; Lightning over-voltage; Lightning performance; Lightning strikes; Transmission tower; Lightning
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-24630 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-246302023-05-29T15:25:19Z Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm Abd Rahman M.S. Ab Kadir M.Z.A. Ab-Rahman M.S. Osman M. Nor S.F.M. 36609854400 25947297000 57211618044 7201930315 57188964617 Electric insulation; Electric power transmission; Flashover; Towers; ANSYS Maxwell; Electric field profiles; Feasibility studies; Lightning activity; Lightning over-voltage; Lightning performance; Lightning strikes; Transmission tower; Lightning Severe lightning overvoltage is regarded to the multiple flashovers on the overhead lines. Therefore, it signifies the needs of having a robust insulation system, especially to those which highly susceptible to lightning strikes. In order to minimize the impact of lightning, it is necessary to evaluate lightning performance of the tower and its components before implementing any proposed design. Therefore, in this work, a feasibility study was done on proposed 275 kV and 132 kV transmission tower with composite crossarm installed. In order to assess the insulation strength of the tower against the lightning activities, lightning caused events i.e. backflashover and shielding failure were applied onto the tower models by using FEM based software. The CFO of the tower insulation were calculated based on the design provided, whereby it was complementary verified by the voltage and electric field profiles of the simulation. For each case, none had shown a voltage magnitude higher than the voltage supposed to possibly cause 50% chance of flashover. � 2019 IEEE. Final 2023-05-29T07:25:19Z 2023-05-29T07:25:19Z 2019 Conference Paper 10.1109/APL.2019.8816041 2-s2.0-85072327440 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072327440&doi=10.1109%2fAPL.2019.8816041&partnerID=40&md5=8b5f39d0be18e786837f7326ba475bc4 https://irepository.uniten.edu.my/handle/123456789/24630 8816041 All Open Access, Green Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Electric insulation; Electric power transmission; Flashover; Towers; ANSYS Maxwell; Electric field profiles; Feasibility studies; Lightning activity; Lightning over-voltage; Lightning performance; Lightning strikes; Transmission tower; Lightning |
author2 |
36609854400 |
author_facet |
36609854400 Abd Rahman M.S. Ab Kadir M.Z.A. Ab-Rahman M.S. Osman M. Nor S.F.M. |
format |
Conference Paper |
author |
Abd Rahman M.S. Ab Kadir M.Z.A. Ab-Rahman M.S. Osman M. Nor S.F.M. |
spellingShingle |
Abd Rahman M.S. Ab Kadir M.Z.A. Ab-Rahman M.S. Osman M. Nor S.F.M. Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
author_sort |
Abd Rahman M.S. |
title |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_short |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_full |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_fullStr |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_full_unstemmed |
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm |
title_sort |
lightning impulse strength of 275 kv and 132 kv tower with composite crossarm |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806427863448027136 |
score |
13.214268 |