Conceptual design of outer tube inspection robot
Periodical maintenance and inspection of the power plant system and its subsystem are deemed necessary to avoid shortage and unplanned shutdown. Boiler is one of the main modules in thermal power plant. The boiler operates under high thermo and mechanical loading that leads to failures caused by deg...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
American Institute of Physics Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-24560 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-245602023-05-29T15:24:35Z Conceptual design of outer tube inspection robot Aziz M.A. Jalal M.F.A. Sahari K.S.M. Leong Y.W. Sekari S.A. 57222438013 37116431100 57218170038 26326032700 57197807171 Periodical maintenance and inspection of the power plant system and its subsystem are deemed necessary to avoid shortage and unplanned shutdown. Boiler is one of the main modules in thermal power plant. The boiler operates under high thermo and mechanical loading that leads to failures caused by degradation, creep, corrosion, and others. One of the critical area for inspection is the welding joint between the boiler header and tubes. In this paper, the conceptual design of the robotic system for inspecting the outer boiler tube condition specifically at the welding joint between the boiler header and tubes is presented. The main standard mechanical components namely passive actuator and motor are determine based on the detailed calculation. � 2019 Author(s). Final 2023-05-29T07:24:35Z 2023-05-29T07:24:35Z 2019 Conference Paper 10.1063/1.5118024 2-s2.0-85070556416 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85070556416&doi=10.1063%2f1.5118024&partnerID=40&md5=dc52e277cd210b02686fbb04d863569b https://irepository.uniten.edu.my/handle/123456789/24560 2129 20016 American Institute of Physics Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Periodical maintenance and inspection of the power plant system and its subsystem are deemed necessary to avoid shortage and unplanned shutdown. Boiler is one of the main modules in thermal power plant. The boiler operates under high thermo and mechanical loading that leads to failures caused by degradation, creep, corrosion, and others. One of the critical area for inspection is the welding joint between the boiler header and tubes. In this paper, the conceptual design of the robotic system for inspecting the outer boiler tube condition specifically at the welding joint between the boiler header and tubes is presented. The main standard mechanical components namely passive actuator and motor are determine based on the detailed calculation. � 2019 Author(s). |
author2 |
57222438013 |
author_facet |
57222438013 Aziz M.A. Jalal M.F.A. Sahari K.S.M. Leong Y.W. Sekari S.A. |
format |
Conference Paper |
author |
Aziz M.A. Jalal M.F.A. Sahari K.S.M. Leong Y.W. Sekari S.A. |
spellingShingle |
Aziz M.A. Jalal M.F.A. Sahari K.S.M. Leong Y.W. Sekari S.A. Conceptual design of outer tube inspection robot |
author_sort |
Aziz M.A. |
title |
Conceptual design of outer tube inspection robot |
title_short |
Conceptual design of outer tube inspection robot |
title_full |
Conceptual design of outer tube inspection robot |
title_fullStr |
Conceptual design of outer tube inspection robot |
title_full_unstemmed |
Conceptual design of outer tube inspection robot |
title_sort |
conceptual design of outer tube inspection robot |
publisher |
American Institute of Physics Inc. |
publishDate |
2023 |
_version_ |
1806427290343571456 |
score |
13.214268 |