Harmonic mitigation in traction supply substation using cascaded H-bridge converter

The conventional three-level inverter has been proposed to act as a recuperating converter in Traction Supply Substation. This converter is mainly used to feed back the regenerative braking energy to the grid. However, passive filter is desired to mitigate the current and voltage harmonics. Therefor...

全面介紹

Saved in:
書目詳細資料
Main Authors: Awalludin A., Toh C.L.
其他作者: 57188984003
格式: Article
出版: Institute of Advanced Engineering and Science 2023
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.uniten.dspace-24159
record_format dspace
spelling my.uniten.dspace-241592023-05-29T14:56:14Z Harmonic mitigation in traction supply substation using cascaded H-bridge converter Awalludin A. Toh C.L. 57188984003 8690228000 The conventional three-level inverter has been proposed to act as a recuperating converter in Traction Supply Substation. This converter is mainly used to feed back the regenerative braking energy to the grid. However, passive filter is desired to mitigate the current and voltage harmonics. Therefore, this paper investigates the possibility to use a seven-level Cascaded H-Bridge (CHB) converter as the recuperating converter without additional filtering. The proposed converter is modeled with MATLAB/Simulink simulation software. It is then simulated with two potential modulation schemes, namely Phase-Shifted PWM (PS-PWM) and Phase-Disposition PWM (PD-PWM). The quality of AC waveforms produced by these two modulation methods is compared and studied. The results show that PS-PWM technique is preferable for this application as it offered a clean AC current waveform with less than 5% harmonic distortion. However, a twenty-one-level CHB was predicted to comply with the 8% voltage harmonic requirement. � 2018 Institute of Advanced Engineering and Science. All rights reserved. Final 2023-05-29T06:56:13Z 2023-05-29T06:56:13Z 2018 Article 10.11591/ijpeds.v9n4.pp1745-1754 2-s2.0-85055705037 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85055705037&doi=10.11591%2fijpeds.v9n4.pp1745-1754&partnerID=40&md5=25dae08eabdfb9cda9a69f6e33f108f8 https://irepository.uniten.edu.my/handle/123456789/24159 9 4 1745 1754 Institute of Advanced Engineering and Science Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description The conventional three-level inverter has been proposed to act as a recuperating converter in Traction Supply Substation. This converter is mainly used to feed back the regenerative braking energy to the grid. However, passive filter is desired to mitigate the current and voltage harmonics. Therefore, this paper investigates the possibility to use a seven-level Cascaded H-Bridge (CHB) converter as the recuperating converter without additional filtering. The proposed converter is modeled with MATLAB/Simulink simulation software. It is then simulated with two potential modulation schemes, namely Phase-Shifted PWM (PS-PWM) and Phase-Disposition PWM (PD-PWM). The quality of AC waveforms produced by these two modulation methods is compared and studied. The results show that PS-PWM technique is preferable for this application as it offered a clean AC current waveform with less than 5% harmonic distortion. However, a twenty-one-level CHB was predicted to comply with the 8% voltage harmonic requirement. � 2018 Institute of Advanced Engineering and Science. All rights reserved.
author2 57188984003
author_facet 57188984003
Awalludin A.
Toh C.L.
format Article
author Awalludin A.
Toh C.L.
spellingShingle Awalludin A.
Toh C.L.
Harmonic mitigation in traction supply substation using cascaded H-bridge converter
author_sort Awalludin A.
title Harmonic mitigation in traction supply substation using cascaded H-bridge converter
title_short Harmonic mitigation in traction supply substation using cascaded H-bridge converter
title_full Harmonic mitigation in traction supply substation using cascaded H-bridge converter
title_fullStr Harmonic mitigation in traction supply substation using cascaded H-bridge converter
title_full_unstemmed Harmonic mitigation in traction supply substation using cascaded H-bridge converter
title_sort harmonic mitigation in traction supply substation using cascaded h-bridge converter
publisher Institute of Advanced Engineering and Science
publishDate 2023
_version_ 1806423796825980928
score 13.250246