Harmonic mitigation in traction supply substation using cascaded H-bridge converter
The conventional three-level inverter has been proposed to act as a recuperating converter in Traction Supply Substation. This converter is mainly used to feed back the regenerative braking energy to the grid. However, passive filter is desired to mitigate the current and voltage harmonics. Therefor...
Saved in:
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Institute of Advanced Engineering and Science
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-24159 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-241592023-05-29T14:56:14Z Harmonic mitigation in traction supply substation using cascaded H-bridge converter Awalludin A. Toh C.L. 57188984003 8690228000 The conventional three-level inverter has been proposed to act as a recuperating converter in Traction Supply Substation. This converter is mainly used to feed back the regenerative braking energy to the grid. However, passive filter is desired to mitigate the current and voltage harmonics. Therefore, this paper investigates the possibility to use a seven-level Cascaded H-Bridge (CHB) converter as the recuperating converter without additional filtering. The proposed converter is modeled with MATLAB/Simulink simulation software. It is then simulated with two potential modulation schemes, namely Phase-Shifted PWM (PS-PWM) and Phase-Disposition PWM (PD-PWM). The quality of AC waveforms produced by these two modulation methods is compared and studied. The results show that PS-PWM technique is preferable for this application as it offered a clean AC current waveform with less than 5% harmonic distortion. However, a twenty-one-level CHB was predicted to comply with the 8% voltage harmonic requirement. � 2018 Institute of Advanced Engineering and Science. All rights reserved. Final 2023-05-29T06:56:13Z 2023-05-29T06:56:13Z 2018 Article 10.11591/ijpeds.v9n4.pp1745-1754 2-s2.0-85055705037 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85055705037&doi=10.11591%2fijpeds.v9n4.pp1745-1754&partnerID=40&md5=25dae08eabdfb9cda9a69f6e33f108f8 https://irepository.uniten.edu.my/handle/123456789/24159 9 4 1745 1754 Institute of Advanced Engineering and Science Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
The conventional three-level inverter has been proposed to act as a recuperating converter in Traction Supply Substation. This converter is mainly used to feed back the regenerative braking energy to the grid. However, passive filter is desired to mitigate the current and voltage harmonics. Therefore, this paper investigates the possibility to use a seven-level Cascaded H-Bridge (CHB) converter as the recuperating converter without additional filtering. The proposed converter is modeled with MATLAB/Simulink simulation software. It is then simulated with two potential modulation schemes, namely Phase-Shifted PWM (PS-PWM) and Phase-Disposition PWM (PD-PWM). The quality of AC waveforms produced by these two modulation methods is compared and studied. The results show that PS-PWM technique is preferable for this application as it offered a clean AC current waveform with less than 5% harmonic distortion. However, a twenty-one-level CHB was predicted to comply with the 8% voltage harmonic requirement. � 2018 Institute of Advanced Engineering and Science. All rights reserved. |
author2 |
57188984003 |
author_facet |
57188984003 Awalludin A. Toh C.L. |
format |
Article |
author |
Awalludin A. Toh C.L. |
spellingShingle |
Awalludin A. Toh C.L. Harmonic mitigation in traction supply substation using cascaded H-bridge converter |
author_sort |
Awalludin A. |
title |
Harmonic mitigation in traction supply substation using cascaded H-bridge converter |
title_short |
Harmonic mitigation in traction supply substation using cascaded H-bridge converter |
title_full |
Harmonic mitigation in traction supply substation using cascaded H-bridge converter |
title_fullStr |
Harmonic mitigation in traction supply substation using cascaded H-bridge converter |
title_full_unstemmed |
Harmonic mitigation in traction supply substation using cascaded H-bridge converter |
title_sort |
harmonic mitigation in traction supply substation using cascaded h-bridge converter |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2023 |
_version_ |
1806423796825980928 |
score |
13.214268 |