Treatment of domestic wastewater with fixed bed biofilm reactor
Fixed bed biofilm reactors were evaluated with three different arrangements of bio-balls. The performance of different arrangements was evaluated based on chemical oxygen demand (COD), total suspended solid (TSS) and mixed liquor suspended solid (MLSS). The three rectors were fabricated and operated...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Science Publishing Corporation Inc
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-24114 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-241142023-05-29T14:55:39Z Treatment of domestic wastewater with fixed bed biofilm reactor Hayder G. Perumulselum P. Alhussian H. 56239664100 57192990515 55430817100 Fixed bed biofilm reactors were evaluated with three different arrangements of bio-balls. The performance of different arrangements was evaluated based on chemical oxygen demand (COD), total suspended solid (TSS) and mixed liquor suspended solid (MLSS). The three rectors were fabricated and operated in lab scale model with real domestic wastewater. Considering the TSS removal efficiency, arrangement one was the best followed by arrangement two and arrangement three. While for COD, arrangement one recorded the highest removal efficiency followed by arrangement two and column. The average COD concentration for arrangement one was 23 while for arrangement two and arrangement three was 25 and 36 mg/l respectively. The overall average effluent TSS concentrations for the arrangement one, two and three were 25, 32 and 45 mg/l respectively. TSS and COD removal was almost the same for arrangement one and arrangement two but arrangement one has the highest among them, and all removal is acceptable under Malaysian standards. Besides that, all the three arrangements have the differences in terms of maintenance and installation. There was no clogging occurred in all the three arrangements. � 2018 Authors. Final 2023-05-29T06:55:39Z 2023-05-29T06:55:39Z 2018 Article 10.14419/ijet.v7i4.35.22314 2-s2.0-85059225716 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85059225716&doi=10.14419%2fijet.v7i4.35.22314&partnerID=40&md5=a2a6db0ea1b2b9dce0639be38c026c23 https://irepository.uniten.edu.my/handle/123456789/24114 7 4 22 25 Science Publishing Corporation Inc Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Fixed bed biofilm reactors were evaluated with three different arrangements of bio-balls. The performance of different arrangements was evaluated based on chemical oxygen demand (COD), total suspended solid (TSS) and mixed liquor suspended solid (MLSS). The three rectors were fabricated and operated in lab scale model with real domestic wastewater. Considering the TSS removal efficiency, arrangement one was the best followed by arrangement two and arrangement three. While for COD, arrangement one recorded the highest removal efficiency followed by arrangement two and column. The average COD concentration for arrangement one was 23 while for arrangement two and arrangement three was 25 and 36 mg/l respectively. The overall average effluent TSS concentrations for the arrangement one, two and three were 25, 32 and 45 mg/l respectively. TSS and COD removal was almost the same for arrangement one and arrangement two but arrangement one has the highest among them, and all removal is acceptable under Malaysian standards. Besides that, all the three arrangements have the differences in terms of maintenance and installation. There was no clogging occurred in all the three arrangements. � 2018 Authors. |
author2 |
56239664100 |
author_facet |
56239664100 Hayder G. Perumulselum P. Alhussian H. |
format |
Article |
author |
Hayder G. Perumulselum P. Alhussian H. |
spellingShingle |
Hayder G. Perumulselum P. Alhussian H. Treatment of domestic wastewater with fixed bed biofilm reactor |
author_sort |
Hayder G. |
title |
Treatment of domestic wastewater with fixed bed biofilm reactor |
title_short |
Treatment of domestic wastewater with fixed bed biofilm reactor |
title_full |
Treatment of domestic wastewater with fixed bed biofilm reactor |
title_fullStr |
Treatment of domestic wastewater with fixed bed biofilm reactor |
title_full_unstemmed |
Treatment of domestic wastewater with fixed bed biofilm reactor |
title_sort |
treatment of domestic wastewater with fixed bed biofilm reactor |
publisher |
Science Publishing Corporation Inc |
publishDate |
2023 |
_version_ |
1806426138048724992 |
score |
13.214268 |