S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing
Ultrasonic testing or commonly known as UT is one of the non-destructive testing technique and widely used in oil and gas industrial inspection. This technique mostly used in defect or crack identification of the pipeline and also used for flaw detection/evaluation, dimensional measurements, and mat...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Science Publishing Corporation Inc
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-24003 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-240032023-05-29T14:54:09Z S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing Ali K. Paw J.K.S. Aizat M.Sulaiman M. Abdalla A.N. Hen C.K. Ding T.J. 36130958600 22951210700 57188663593 56050971600 36994481200 38863172300 Ultrasonic testing or commonly known as UT is one of the non-destructive testing technique and widely used in oil and gas industrial inspection. This technique mostly used in defect or crack identification of the pipeline and also used for flaw detection/evaluation, dimensional measurements, and material characterization. This paper presents the effect of heat treatment for S55C carbon steel in attenuation measurement by using ultrasonic testing including annealing, tempering, and quenching process. Seawater and oil are used as a medium of quenching process. The fixed excitation frequency at 4 MHz is used and 0 degrees with double crystal is implemented in this measurement. The thicknesses of blocks used are as the sample from 30mm until 80mm. The result shows that the measurement of material attenuation will be decreased after annealing, tempering and quenching process from 40% until 99% compared to before the heat treatment process. The highest attenuation decreasing can be seen on the sample block with the 30mm thickness in the heat treatment process. � 2018 Authors. Final 2023-05-29T06:54:09Z 2023-05-29T06:54:09Z 2018 Article 10.14419/ijet.v7i4.35.22904 2-s2.0-85059245697 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85059245697&doi=10.14419%2fijet.v7i4.35.22904&partnerID=40&md5=4cd03d6fb4220ab504498e22be80ac50 https://irepository.uniten.edu.my/handle/123456789/24003 7 4 527 533 All Open Access, Bronze, Green Science Publishing Corporation Inc Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Ultrasonic testing or commonly known as UT is one of the non-destructive testing technique and widely used in oil and gas industrial inspection. This technique mostly used in defect or crack identification of the pipeline and also used for flaw detection/evaluation, dimensional measurements, and material characterization. This paper presents the effect of heat treatment for S55C carbon steel in attenuation measurement by using ultrasonic testing including annealing, tempering, and quenching process. Seawater and oil are used as a medium of quenching process. The fixed excitation frequency at 4 MHz is used and 0 degrees with double crystal is implemented in this measurement. The thicknesses of blocks used are as the sample from 30mm until 80mm. The result shows that the measurement of material attenuation will be decreased after annealing, tempering and quenching process from 40% until 99% compared to before the heat treatment process. The highest attenuation decreasing can be seen on the sample block with the 30mm thickness in the heat treatment process. � 2018 Authors. |
author2 |
36130958600 |
author_facet |
36130958600 Ali K. Paw J.K.S. Aizat M.Sulaiman M. Abdalla A.N. Hen C.K. Ding T.J. |
format |
Article |
author |
Ali K. Paw J.K.S. Aizat M.Sulaiman M. Abdalla A.N. Hen C.K. Ding T.J. |
spellingShingle |
Ali K. Paw J.K.S. Aizat M.Sulaiman M. Abdalla A.N. Hen C.K. Ding T.J. S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing |
author_sort |
Ali K. |
title |
S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing |
title_short |
S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing |
title_full |
S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing |
title_fullStr |
S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing |
title_full_unstemmed |
S55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing |
title_sort |
s55c carbon steel for heat treatment process with different medium in attenuation measurement using ultrasonic testing |
publisher |
Science Publishing Corporation Inc |
publishDate |
2023 |
_version_ |
1806425492995178496 |
score |
13.214268 |