Profile of cold-formed steel for compression member design a basic combination performance
Experiment previously showed several findings that the strength of cold-formed steel cross-section are not the same, where web strength and flange strength do not give the same response when receiving the axial load. This occurs not only because of a shift in the center point of the force due to def...