Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates

Driers (materials); Environmental impact; Evaporative cooling systems; Refrigerants; Thermoelectric equipment; Desiccant cooling; Desiccant cooling systems; Desiccant wheels; Evaporative cooling; Experimental investigations; Humidity conditions; Laboratory conditions; Tropical countries; Air conditi...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdullah K., Saepul Uyun A., Muhammad Nur S., Bamahry A., Imanda R., Meurah Indra Mahlia T.
Other Authors: 55973139100
Format: Conference Paper
Published: EDP Sciences 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-23834
record_format dspace
spelling my.uniten.dspace-238342023-05-29T14:52:15Z Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates Abdullah K. Saepul Uyun A. Muhammad Nur S. Bamahry A. Imanda R. Meurah Indra Mahlia T. 55973139100 16067509800 57202005106 57202009673 57217953192 56997615100 Driers (materials); Environmental impact; Evaporative cooling systems; Refrigerants; Thermoelectric equipment; Desiccant cooling; Desiccant cooling systems; Desiccant wheels; Evaporative cooling; Experimental investigations; Humidity conditions; Laboratory conditions; Tropical countries; Air conditioning Indonesia lies in the tropical climate which requires air conditioning to increase working productivity of the people. Up to now people are still using the compressive cooling system which uses Freon as the refrigerant, which have been known to have a negative environmental impact. Therefore, new cooling system which is environmentally friendly is now needed. Desiccant cooling system manipulates the humidity condition of outside air in such a way so that the final temperature should become at 25 �C and RH of 65 %. Since it does not require refrigerant, a desiccant cooling has the potential to be developed in a tropical country like Indonesia. In this study an experimental desiccant cooling system has been designed and constructed and tested under laboratory condition. Experimental results have shown that the resulting air temperature was 26.1 �C with RH of 55.6 %, and average cooling capacity was 0.425 kW. The COP was found to be 0.44. � The Authors, published by EDP Sciences, 2018. Final 2023-05-29T06:52:15Z 2023-05-29T06:52:15Z 2018 Conference Paper 10.1051/matecconf/201816401022 2-s2.0-85046771668 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85046771668&doi=10.1051%2fmatecconf%2f201816401022&partnerID=40&md5=9a4f0afb54d4db87aead46d77a65b1ef https://irepository.uniten.edu.my/handle/123456789/23834 164 1022 All Open Access, Gold, Green EDP Sciences Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Driers (materials); Environmental impact; Evaporative cooling systems; Refrigerants; Thermoelectric equipment; Desiccant cooling; Desiccant cooling systems; Desiccant wheels; Evaporative cooling; Experimental investigations; Humidity conditions; Laboratory conditions; Tropical countries; Air conditioning
author2 55973139100
author_facet 55973139100
Abdullah K.
Saepul Uyun A.
Muhammad Nur S.
Bamahry A.
Imanda R.
Meurah Indra Mahlia T.
format Conference Paper
author Abdullah K.
Saepul Uyun A.
Muhammad Nur S.
Bamahry A.
Imanda R.
Meurah Indra Mahlia T.
spellingShingle Abdullah K.
Saepul Uyun A.
Muhammad Nur S.
Bamahry A.
Imanda R.
Meurah Indra Mahlia T.
Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
author_sort Abdullah K.
title Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
title_short Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
title_full Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
title_fullStr Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
title_full_unstemmed Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates
title_sort experimental investigation of air conditioner using the desiccant cooling system in equatorial climates
publisher EDP Sciences
publishDate 2023
_version_ 1806423424444137472
score 13.209306