Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E

Identification of weak load buses which contributes to voltage instability problem is crucial in order for an appropriate mitigation action to be executed. The current power system transmission is not only stressed to deliver high load demand at the receiving end but also facing new challenges broug...

Full description

Saved in:
Bibliographic Details
Main Authors: Verayiah R., Mohamed A.
Other Authors: 26431682500
Format: Article
Published: Institute of Advanced Engineering and Science 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-23630
record_format dspace
spelling my.uniten.dspace-236302023-05-29T14:50:37Z Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E Verayiah R. Mohamed A. 26431682500 57195440511 Identification of weak load buses which contributes to voltage instability problem is crucial in order for an appropriate mitigation action to be executed. The current power system transmission is not only stressed to deliver high load demand at the receiving end but also facing new challenges brought by the penetratrion of renewable energy sources. This new scenario requires power system operation and analysis to be robust and fast in detecting the accurate weak load bus for correction action. Due to this, many online indices to detect weak load bus during power system contingency have been developed. Nevertheless, LQP_LT is of the latest index developed which ultimately has the reactive power tracing capability for weak load bus detection and generate priority ranking list of the weak load buses. This index was tested on IEEE 14 bus test system for different contingency scenarios. The results obtained from the LQP_LT index is compared and validated with the PV and QV analyses obtained using industrial graded PSS/E software. It was concluded that the LQP_LT index is found to be robust, efficient and need less computation time as compared to the execution of voltage stability analysis using the PSS/E Tool. � 2018 Institute of Advanced Engineering and Science. All rights reserved. Final 2023-05-29T06:50:37Z 2023-05-29T06:50:37Z 2018 Article 10.11591/ijeecs.v12.i2.pp577-584 2-s2.0-85051780807 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85051780807&doi=10.11591%2fijeecs.v12.i2.pp577-584&partnerID=40&md5=b3ab64306cd7f0b46b04fc208ba790a4 https://irepository.uniten.edu.my/handle/123456789/23630 12 2 577 584 All Open Access, Hybrid Gold, Green Institute of Advanced Engineering and Science Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Identification of weak load buses which contributes to voltage instability problem is crucial in order for an appropriate mitigation action to be executed. The current power system transmission is not only stressed to deliver high load demand at the receiving end but also facing new challenges brought by the penetratrion of renewable energy sources. This new scenario requires power system operation and analysis to be robust and fast in detecting the accurate weak load bus for correction action. Due to this, many online indices to detect weak load bus during power system contingency have been developed. Nevertheless, LQP_LT is of the latest index developed which ultimately has the reactive power tracing capability for weak load bus detection and generate priority ranking list of the weak load buses. This index was tested on IEEE 14 bus test system for different contingency scenarios. The results obtained from the LQP_LT index is compared and validated with the PV and QV analyses obtained using industrial graded PSS/E software. It was concluded that the LQP_LT index is found to be robust, efficient and need less computation time as compared to the execution of voltage stability analysis using the PSS/E Tool. � 2018 Institute of Advanced Engineering and Science. All rights reserved.
author2 26431682500
author_facet 26431682500
Verayiah R.
Mohamed A.
format Article
author Verayiah R.
Mohamed A.
spellingShingle Verayiah R.
Mohamed A.
Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E
author_sort Verayiah R.
title Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E
title_short Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E
title_full Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E
title_fullStr Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E
title_full_unstemmed Comparison of weak load bus detection using LQP_LT index with PV and QV analysis of PSS/E
title_sort comparison of weak load bus detection using lqp_lt index with pv and qv analysis of pss/e
publisher Institute of Advanced Engineering and Science
publishDate 2023
_version_ 1806425859235512320
score 13.211869