Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium
Atrium is a modern architectural design of buildings that has an open space at the middle and contains multiple floors. In case of a fire in an atrium, the movement of the smoke plume is influenced by several factors. A CFD simulation using fire dynamic simulator (FDS6) software is conducted to inve...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
American Institute of Physics Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-23555 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-235552023-05-29T14:50:13Z Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium Mutafi M.A. Nasif M.S. Pao W. Ismail F.B. 57196442142 55188481100 7003342282 58027086700 Atrium is a modern architectural design of buildings that has an open space at the middle and contains multiple floors. In case of a fire in an atrium, the movement of the smoke plume is influenced by several factors. A CFD simulation using fire dynamic simulator (FDS6) software is conducted to investigate the effect of fire compartment opening width and heat release rate on horizontal Projections of smoke plume in a full scale atrium with down stand depths of 1m and 0.75m. It was found that, when the fire compartment opening width is small the smoke plume tends to flow away from the atrium structure. However, when the heat release rate is small the smoke plume flows closer to the atrium structure. � 2018 Author(s). Final 2023-05-29T06:50:13Z 2023-05-29T06:50:13Z 2018 Conference Paper 10.1063/1.5075595 2-s2.0-85057335230 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85057335230&doi=10.1063%2f1.5075595&partnerID=40&md5=8d530da5d82d7f3c504c6ec70607cc09 https://irepository.uniten.edu.my/handle/123456789/23555 2035 70005 American Institute of Physics Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Atrium is a modern architectural design of buildings that has an open space at the middle and contains multiple floors. In case of a fire in an atrium, the movement of the smoke plume is influenced by several factors. A CFD simulation using fire dynamic simulator (FDS6) software is conducted to investigate the effect of fire compartment opening width and heat release rate on horizontal Projections of smoke plume in a full scale atrium with down stand depths of 1m and 0.75m. It was found that, when the fire compartment opening width is small the smoke plume tends to flow away from the atrium structure. However, when the heat release rate is small the smoke plume flows closer to the atrium structure. � 2018 Author(s). |
author2 |
57196442142 |
author_facet |
57196442142 Mutafi M.A. Nasif M.S. Pao W. Ismail F.B. |
format |
Conference Paper |
author |
Mutafi M.A. Nasif M.S. Pao W. Ismail F.B. |
spellingShingle |
Mutafi M.A. Nasif M.S. Pao W. Ismail F.B. Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium |
author_sort |
Mutafi M.A. |
title |
Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium |
title_short |
Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium |
title_full |
Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium |
title_fullStr |
Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium |
title_full_unstemmed |
Numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium |
title_sort |
numerical investigation on the effect of fire compartment opening width and heat release rate on the horizontal projection of smoke plume in a full-scale atrium |
publisher |
American Institute of Physics Inc. |
publishDate |
2023 |
_version_ |
1806427784372813824 |
score |
13.222552 |