Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators
This paper presents the experimental verification of a 2 kW battery energy storage system (BESS). The BESS comprises a full-bridge bidirectional isolated dc-dc converter and a PWM converter that is intended for integration with a photovoltaic (PV) generator, resulting in leveling of the intermittent...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Hindawi Limited
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-23477 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-234772023-05-29T14:40:51Z Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators Singh R. Taghizadeh S. Tan N.M.L. Mekhilef S. 57189853244 56483025000 24537965000 57928298500 This paper presents the experimental verification of a 2 kW battery energy storage system (BESS). The BESS comprises a full-bridge bidirectional isolated dc-dc converter and a PWM converter that is intended for integration with a photovoltaic (PV) generator, resulting in leveling of the intermittent output power from the PV generator at the utility side. A phase-shift controller is also employed to manage the charging and discharging operations of the BESS based on PV output power and battery voltage. Moreover, a current controller that uses the d - q synchronous reference frame is proposed to regulate the dc voltage at the high-voltage side (HVS) to ensure that the voltage ratio of the HVS with low-voltage side (LVS) is equivalent to the transformer turns ratio. The proposed controllers allow fast response to changes in real power requirements and results in unity power factor current injection at the utility side. In addition, the efficient active power injection is achieved as the switching losses are minimized. The peak efficiency of the bidirectional isolated dc-dc converter is measured up to 95.4% during battery charging and 95.1% for battery discharging. � 2017 Rajkiran Singh et al. Final 2023-05-29T06:40:51Z 2023-05-29T06:40:51Z 2017 Article 10.1155/2017/8158964 2-s2.0-85012203448 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012203448&doi=10.1155%2f2017%2f8158964&partnerID=40&md5=176d0f142167c33b91afa0f5d448c1db https://irepository.uniten.edu.my/handle/123456789/23477 2017 8158964 All Open Access, Gold, Green Hindawi Limited Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
This paper presents the experimental verification of a 2 kW battery energy storage system (BESS). The BESS comprises a full-bridge bidirectional isolated dc-dc converter and a PWM converter that is intended for integration with a photovoltaic (PV) generator, resulting in leveling of the intermittent output power from the PV generator at the utility side. A phase-shift controller is also employed to manage the charging and discharging operations of the BESS based on PV output power and battery voltage. Moreover, a current controller that uses the d - q synchronous reference frame is proposed to regulate the dc voltage at the high-voltage side (HVS) to ensure that the voltage ratio of the HVS with low-voltage side (LVS) is equivalent to the transformer turns ratio. The proposed controllers allow fast response to changes in real power requirements and results in unity power factor current injection at the utility side. In addition, the efficient active power injection is achieved as the switching losses are minimized. The peak efficiency of the bidirectional isolated dc-dc converter is measured up to 95.4% during battery charging and 95.1% for battery discharging. � 2017 Rajkiran Singh et al. |
author2 |
57189853244 |
author_facet |
57189853244 Singh R. Taghizadeh S. Tan N.M.L. Mekhilef S. |
format |
Article |
author |
Singh R. Taghizadeh S. Tan N.M.L. Mekhilef S. |
spellingShingle |
Singh R. Taghizadeh S. Tan N.M.L. Mekhilef S. Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators |
author_sort |
Singh R. |
title |
Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators |
title_short |
Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators |
title_full |
Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators |
title_fullStr |
Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators |
title_full_unstemmed |
Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators |
title_sort |
experimental verification of a battery energy storage system for integration with photovoltaic generators |
publisher |
Hindawi Limited |
publishDate |
2023 |
_version_ |
1806427611613626368 |
score |
13.222552 |