A fully-automated retinal blood vessels detection using filling algorithm

This paper proposes a fully-automated retinal blood vessels detection method using image preprocessing, multi-scale line detector and post-processing approaches. In this method, a filling algorithm applied on the green channel has solved the vessel problem with central reflex. Moreover, the sum of m...

Full description

Saved in:
Bibliographic Details
Main Authors: Mustafa N.B.A., Zaki W.M.D.W., Hussain A., Hamzah J.C.
Other Authors: 57191952020
Format: Article
Published: International Information Institute Ltd. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-23393
record_format dspace
spelling my.uniten.dspace-233932023-05-29T14:40:06Z A fully-automated retinal blood vessels detection using filling algorithm Mustafa N.B.A. Zaki W.M.D.W. Hussain A. Hamzah J.C. 57191952020 8507300300 57208481391 36702655100 This paper proposes a fully-automated retinal blood vessels detection method using image preprocessing, multi-scale line detector and post-processing approaches. In this method, a filling algorithm applied on the green channel has solved the vessel problem with central reflex. Moreover, the sum of multi-directional top-hat transformation has successfully enhanced all vessels including thin and tortuous vessels, as well as reduced the optic disk effect in retinal images. The proposed method has shown to be comparable to previous work. In addition, experimental work conducted using HRF images has also shown promising results with average 79.01% (sensitivity), 94.64%(specificity) and 93.30%(accuracy). � 2017 International Information Institute. Final 2023-05-29T06:40:05Z 2023-05-29T06:40:05Z 2017 Article 2-s2.0-85033386345 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033386345&partnerID=40&md5=47eaef1b6dc2621756bc72f6a2f07279 https://irepository.uniten.edu.my/handle/123456789/23393 20 1 665 673 International Information Institute Ltd. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description This paper proposes a fully-automated retinal blood vessels detection method using image preprocessing, multi-scale line detector and post-processing approaches. In this method, a filling algorithm applied on the green channel has solved the vessel problem with central reflex. Moreover, the sum of multi-directional top-hat transformation has successfully enhanced all vessels including thin and tortuous vessels, as well as reduced the optic disk effect in retinal images. The proposed method has shown to be comparable to previous work. In addition, experimental work conducted using HRF images has also shown promising results with average 79.01% (sensitivity), 94.64%(specificity) and 93.30%(accuracy). � 2017 International Information Institute.
author2 57191952020
author_facet 57191952020
Mustafa N.B.A.
Zaki W.M.D.W.
Hussain A.
Hamzah J.C.
format Article
author Mustafa N.B.A.
Zaki W.M.D.W.
Hussain A.
Hamzah J.C.
spellingShingle Mustafa N.B.A.
Zaki W.M.D.W.
Hussain A.
Hamzah J.C.
A fully-automated retinal blood vessels detection using filling algorithm
author_sort Mustafa N.B.A.
title A fully-automated retinal blood vessels detection using filling algorithm
title_short A fully-automated retinal blood vessels detection using filling algorithm
title_full A fully-automated retinal blood vessels detection using filling algorithm
title_fullStr A fully-automated retinal blood vessels detection using filling algorithm
title_full_unstemmed A fully-automated retinal blood vessels detection using filling algorithm
title_sort fully-automated retinal blood vessels detection using filling algorithm
publisher International Information Institute Ltd.
publishDate 2023
_version_ 1806427566273200128
score 13.222552