A fully-automated retinal blood vessels detection using filling algorithm
This paper proposes a fully-automated retinal blood vessels detection method using image preprocessing, multi-scale line detector and post-processing approaches. In this method, a filling algorithm applied on the green channel has solved the vessel problem with central reflex. Moreover, the sum of m...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
International Information Institute Ltd.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-23393 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-233932023-05-29T14:40:06Z A fully-automated retinal blood vessels detection using filling algorithm Mustafa N.B.A. Zaki W.M.D.W. Hussain A. Hamzah J.C. 57191952020 8507300300 57208481391 36702655100 This paper proposes a fully-automated retinal blood vessels detection method using image preprocessing, multi-scale line detector and post-processing approaches. In this method, a filling algorithm applied on the green channel has solved the vessel problem with central reflex. Moreover, the sum of multi-directional top-hat transformation has successfully enhanced all vessels including thin and tortuous vessels, as well as reduced the optic disk effect in retinal images. The proposed method has shown to be comparable to previous work. In addition, experimental work conducted using HRF images has also shown promising results with average 79.01% (sensitivity), 94.64%(specificity) and 93.30%(accuracy). � 2017 International Information Institute. Final 2023-05-29T06:40:05Z 2023-05-29T06:40:05Z 2017 Article 2-s2.0-85033386345 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033386345&partnerID=40&md5=47eaef1b6dc2621756bc72f6a2f07279 https://irepository.uniten.edu.my/handle/123456789/23393 20 1 665 673 International Information Institute Ltd. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
This paper proposes a fully-automated retinal blood vessels detection method using image preprocessing, multi-scale line detector and post-processing approaches. In this method, a filling algorithm applied on the green channel has solved the vessel problem with central reflex. Moreover, the sum of multi-directional top-hat transformation has successfully enhanced all vessels including thin and tortuous vessels, as well as reduced the optic disk effect in retinal images. The proposed method has shown to be comparable to previous work. In addition, experimental work conducted using HRF images has also shown promising results with average 79.01% (sensitivity), 94.64%(specificity) and 93.30%(accuracy). � 2017 International Information Institute. |
author2 |
57191952020 |
author_facet |
57191952020 Mustafa N.B.A. Zaki W.M.D.W. Hussain A. Hamzah J.C. |
format |
Article |
author |
Mustafa N.B.A. Zaki W.M.D.W. Hussain A. Hamzah J.C. |
spellingShingle |
Mustafa N.B.A. Zaki W.M.D.W. Hussain A. Hamzah J.C. A fully-automated retinal blood vessels detection using filling algorithm |
author_sort |
Mustafa N.B.A. |
title |
A fully-automated retinal blood vessels detection using filling algorithm |
title_short |
A fully-automated retinal blood vessels detection using filling algorithm |
title_full |
A fully-automated retinal blood vessels detection using filling algorithm |
title_fullStr |
A fully-automated retinal blood vessels detection using filling algorithm |
title_full_unstemmed |
A fully-automated retinal blood vessels detection using filling algorithm |
title_sort |
fully-automated retinal blood vessels detection using filling algorithm |
publisher |
International Information Institute Ltd. |
publishDate |
2023 |
_version_ |
1806427566273200128 |
score |
13.222552 |