Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies

Computational fluid dynamics; Computer software; Contamination; CFD simulations; Fire dynamic simulators; Flowthrough; Numerical investigations; Smoke

Saved in:
Bibliographic Details
Main Authors: Mutafi M.A., Nasif M.S., Pao W., Ismail F.B.
Other Authors: 57196442142
Format: Conference Paper
Published: Institute of Physics Publishing 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-23075
record_format dspace
spelling my.uniten.dspace-230752023-05-29T14:37:41Z Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies Mutafi M.A. Nasif M.S. Pao W. Ismail F.B. 57196442142 55188481100 7003342282 58027086700 Computational fluid dynamics; Computer software; Contamination; CFD simulations; Fire dynamic simulators; Flowthrough; Numerical investigations; Smoke Atrium is a modern architectural design of buildings that has an open space at the middle and contains several floors. In atrium structure the smoke due to fire can easily flow through the open spaces and causes smoke contamination. CFD simulation using fire dynamic simulator (FDS) software is conducted in this work, to investigate the effect of balcony open upstand on smoke contamination in atrium's balconies and compare it with balconies with solid upstand. It was found that in case of open upstand, the smoke contamination occurrence decreased inside the balcony comparing with balconies with solid upstand. � 2017 Published under licence by IOP Publishing Ltd. Final 2023-05-29T06:37:41Z 2023-05-29T06:37:41Z 2017 Conference Paper 10.1088/1742-6596/908/1/012038 2-s2.0-85034213606 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85034213606&doi=10.1088%2f1742-6596%2f908%2f1%2f012038&partnerID=40&md5=fadf303d5d07d1e422b4047784a09ac9 https://irepository.uniten.edu.my/handle/123456789/23075 908 1 12038 All Open Access, Gold Institute of Physics Publishing Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Computational fluid dynamics; Computer software; Contamination; CFD simulations; Fire dynamic simulators; Flowthrough; Numerical investigations; Smoke
author2 57196442142
author_facet 57196442142
Mutafi M.A.
Nasif M.S.
Pao W.
Ismail F.B.
format Conference Paper
author Mutafi M.A.
Nasif M.S.
Pao W.
Ismail F.B.
spellingShingle Mutafi M.A.
Nasif M.S.
Pao W.
Ismail F.B.
Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
author_sort Mutafi M.A.
title Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
title_short Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
title_full Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
title_fullStr Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
title_full_unstemmed Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
title_sort numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies
publisher Institute of Physics Publishing
publishDate 2023
_version_ 1806425631792037888
score 13.222552