Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]

P-V curve and V-Q curve (often term as Q-V curve) are widely used for planning and operation studies. The P-V curve and V-Q curve of an unbalanced three-phase system, unlike the balanced three-phase system, may not have similar loading margin (LM) and reactive power margin (RPM) on each phase. There...

Full description

Saved in:
Bibliographic Details
Main Authors: Ramasamy A.K., Verayiah R., Abidin I.Z., Gunalan S., Perumal P.
Other Authors: 16023154400
Format: Article
Published: Wydawnictwo SIGMA - N O T Sp. z o.o. 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-22999
record_format dspace
spelling my.uniten.dspace-229992023-05-29T14:14:02Z Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych] Ramasamy A.K. Verayiah R. Abidin I.Z. Gunalan S. Perumal P. 16023154400 26431682500 35606640500 55549473300 57094757300 P-V curve and V-Q curve (often term as Q-V curve) are widely used for planning and operation studies. The P-V curve and V-Q curve of an unbalanced three-phase system, unlike the balanced three-phase system, may not have similar loading margin (LM) and reactive power margin (RPM) on each phase. Therefore, DIgSILENT Programming Language (DPL) has been used to study the maximum loading point (MLP), critical point (CP), and also minimum reactive power point (MRPP) on each phase of an unbalanced three-phase system with different static loads. The tracing direction of P-V curve of each phase and the LM and RPM of each phase obtained from the P-V curve and V-Q curve for different static loads are also discussed. On top of that, continuation power flow (CPF) has become a common method to study the MLP. Hence, a simple 2-bus balanced three-phase system is used to validate the result obtained from the DIgSILENT with CPF method. � 2016, Wydawnictwo SIGMA - N O T Sp. z o.o. All rights reserved. Final 2023-05-29T06:14:02Z 2023-05-29T06:14:02Z 2016 Article 10.15199/48.2016.01.39 2-s2.0-84953236143 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84953236143&doi=10.15199%2f48.2016.01.39&partnerID=40&md5=f7a87c743083a5f522501283ce953278 https://irepository.uniten.edu.my/handle/123456789/22999 92 1 159 165 Wydawnictwo SIGMA - N O T Sp. z o.o. Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description P-V curve and V-Q curve (often term as Q-V curve) are widely used for planning and operation studies. The P-V curve and V-Q curve of an unbalanced three-phase system, unlike the balanced three-phase system, may not have similar loading margin (LM) and reactive power margin (RPM) on each phase. Therefore, DIgSILENT Programming Language (DPL) has been used to study the maximum loading point (MLP), critical point (CP), and also minimum reactive power point (MRPP) on each phase of an unbalanced three-phase system with different static loads. The tracing direction of P-V curve of each phase and the LM and RPM of each phase obtained from the P-V curve and V-Q curve for different static loads are also discussed. On top of that, continuation power flow (CPF) has become a common method to study the MLP. Hence, a simple 2-bus balanced three-phase system is used to validate the result obtained from the DIgSILENT with CPF method. � 2016, Wydawnictwo SIGMA - N O T Sp. z o.o. All rights reserved.
author2 16023154400
author_facet 16023154400
Ramasamy A.K.
Verayiah R.
Abidin I.Z.
Gunalan S.
Perumal P.
format Article
author Ramasamy A.K.
Verayiah R.
Abidin I.Z.
Gunalan S.
Perumal P.
spellingShingle Ramasamy A.K.
Verayiah R.
Abidin I.Z.
Gunalan S.
Perumal P.
Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]
author_sort Ramasamy A.K.
title Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]
title_short Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]
title_full Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]
title_fullStr Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]
title_full_unstemmed Study on P-V Curve and V-Q curve of an unbalanced three- phase system with different static loads [Analiza krzywych P-W i V-Q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]
title_sort study on p-v curve and v-q curve of an unbalanced three- phase system with different static loads [analiza krzywych p-w i v-q w niezr�wnowa?onym uk?adzie tr�jfazowym o r�?nych obci??eniach statycznych]
publisher Wydawnictwo SIGMA - N O T Sp. z o.o.
publishDate 2023
_version_ 1806424033358512128
score 13.214268