CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time

Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activa...

Full description

Saved in:
Bibliographic Details
Main Authors: Nasif M.S., Fekry M., Ismail F.B.
Other Authors: 55188481100
Format: Article
Published: Asian Research Publishing Network 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-22916
record_format dspace
spelling my.uniten.dspace-229162023-05-29T14:13:23Z CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time Nasif M.S. Fekry M. Ismail F.B. 55188481100 57192662727 58027086700 Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90�) to 60�, 30� and parallel to the flow (0�) has resulted in increasing t sprinkler activation time by about 8%, 84%, and 163% respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation. � 2006-2016 Asian Research Publishing Network (ARPN). Final 2023-05-29T06:13:23Z 2023-05-29T06:13:23Z 2016 Article 2-s2.0-85007273692 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85007273692&partnerID=40&md5=f6a848e67b2602b3c8cc11cbe54e9eed https://irepository.uniten.edu.my/handle/123456789/22916 11 22 12919 12922 Asian Research Publishing Network Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90�) to 60�, 30� and parallel to the flow (0�) has resulted in increasing t sprinkler activation time by about 8%, 84%, and 163% respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation. � 2006-2016 Asian Research Publishing Network (ARPN).
author2 55188481100
author_facet 55188481100
Nasif M.S.
Fekry M.
Ismail F.B.
format Article
author Nasif M.S.
Fekry M.
Ismail F.B.
spellingShingle Nasif M.S.
Fekry M.
Ismail F.B.
CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
author_sort Nasif M.S.
title CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
title_short CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
title_full CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
title_fullStr CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
title_full_unstemmed CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
title_sort cfd investigation on the effect of varying fire sprinkler orientation on sprinkler activation time
publisher Asian Research Publishing Network
publishDate 2023
_version_ 1806425857953103872
score 13.222552