Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients

Mathematical modelling of glucose-insulin system is significantly important to understand the body regulation control, to analyze experimental data based on clinical trials, to identify and quantify relevant physiological parameters, to design proper clinical trials and to assess diabetes therapies....

Full description

Saved in:
Bibliographic Details
Main Authors: Jamaludin U.K., Suhaimi F.M., Razak N.N.A., Dzaharudin F., Ralib A.M., Mat Nor M.B.
Other Authors: 55330889600
Format: Article
Published: Asian Research Publishing Network 2023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uniten.dspace-22907
record_format dspace
spelling my.uniten.dspace-229072023-05-29T14:13:17Z Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients Jamaludin U.K. Suhaimi F.M. Razak N.N.A. Dzaharudin F. Ralib A.M. Mat Nor M.B. 55330889600 36247893200 37059587300 35219916100 37031770900 57226799207 Mathematical modelling of glucose-insulin system is significantly important to understand the body regulation control, to analyze experimental data based on clinical trials, to identify and quantify relevant physiological parameters, to design proper clinical trials and to assess diabetes therapies. In general, critically ill patients with blood glucose concentrations between 10.0 to 12.2 mmol/l is identified to develop an acute hyperglycaemia or high blood glucose (BG).Thus, to monitor hyperglycaemia among critically ill patients, this study is focused on observing the glucose-insulin system behaviour based on 40 patients' clinical data collected in Hospital Tengku Ampuan Afzan, Kuantan, Pahang with clinically validated mathematical glucose-insulin model. By using this model, a critical model-based parameter known as insulin sensitivity (SI) that illustrates patient's severity were identified hourly for all patients whose on insulin infusion therapy protocol for average four to six days. The results show that a BG normal distribution is attained with median kurtosis of 2.72. While, the 40 patient-specific SI indicate that an outliers-prone distribution occurred as kurtosis 3.96. Thus, abrupt changes in SI is basically due to chaotic interaction between blood glucose and insulin concentrations in bloodstreams. Also, the glucose-insulin behaviour pattern among these 40 critically ill patients might be varied due to their main diagnostics illness such as acute kidney failure, cardiovascular disease, etc. Overall, these results might assist clinicians and researchers to understand the glucose-insulin behaviour based on patient's severity illness and helps to inform glycaemic control protocol development in a larger group of critically ill patients. � 2006-2016 Asian Research Publishing Network (ARPN). Final 2023-05-29T06:13:17Z 2023-05-29T06:13:17Z 2016 Article 2-s2.0-85010369717 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85010369717&partnerID=40&md5=9f539d7a88d9ffbf4c4c1e8dbdabdc29 https://irepository.uniten.edu.my/handle/123456789/22907 11 18 10899 10903 Asian Research Publishing Network Scopus
institution Universiti Tenaga Nasional
building UNITEN Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tenaga Nasional
content_source UNITEN Institutional Repository
url_provider http://dspace.uniten.edu.my/
description Mathematical modelling of glucose-insulin system is significantly important to understand the body regulation control, to analyze experimental data based on clinical trials, to identify and quantify relevant physiological parameters, to design proper clinical trials and to assess diabetes therapies. In general, critically ill patients with blood glucose concentrations between 10.0 to 12.2 mmol/l is identified to develop an acute hyperglycaemia or high blood glucose (BG).Thus, to monitor hyperglycaemia among critically ill patients, this study is focused on observing the glucose-insulin system behaviour based on 40 patients' clinical data collected in Hospital Tengku Ampuan Afzan, Kuantan, Pahang with clinically validated mathematical glucose-insulin model. By using this model, a critical model-based parameter known as insulin sensitivity (SI) that illustrates patient's severity were identified hourly for all patients whose on insulin infusion therapy protocol for average four to six days. The results show that a BG normal distribution is attained with median kurtosis of 2.72. While, the 40 patient-specific SI indicate that an outliers-prone distribution occurred as kurtosis 3.96. Thus, abrupt changes in SI is basically due to chaotic interaction between blood glucose and insulin concentrations in bloodstreams. Also, the glucose-insulin behaviour pattern among these 40 critically ill patients might be varied due to their main diagnostics illness such as acute kidney failure, cardiovascular disease, etc. Overall, these results might assist clinicians and researchers to understand the glucose-insulin behaviour based on patient's severity illness and helps to inform glycaemic control protocol development in a larger group of critically ill patients. � 2006-2016 Asian Research Publishing Network (ARPN).
author2 55330889600
author_facet 55330889600
Jamaludin U.K.
Suhaimi F.M.
Razak N.N.A.
Dzaharudin F.
Ralib A.M.
Mat Nor M.B.
format Article
author Jamaludin U.K.
Suhaimi F.M.
Razak N.N.A.
Dzaharudin F.
Ralib A.M.
Mat Nor M.B.
spellingShingle Jamaludin U.K.
Suhaimi F.M.
Razak N.N.A.
Dzaharudin F.
Ralib A.M.
Mat Nor M.B.
Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients
author_sort Jamaludin U.K.
title Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients
title_short Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients
title_full Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients
title_fullStr Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients
title_full_unstemmed Mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients
title_sort mathematical modelling of glucose-insulin system behaviour in hospital tengku ampuan afzan intensive care unit patients
publisher Asian Research Publishing Network
publishDate 2023
_version_ 1806428357709004800
score 13.214268