Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage
Chemical analysis; Differential scanning calorimetry; Economic analysis; Heat storage; Latent heat; Melting point; Phase change materials; Polyethylene glycols; Polyethylenes; Reliability analysis; Solar energy; Thermal cycling; Thermal energy; Accelerated thermal cycles; Compositional stability; Di...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
Elsevier B.V.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-22815 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-228152023-05-29T14:12:25Z Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage Sharma R.K. Ganesan P. Tyagi V.V. Mahlia T.M.I. 56424398200 55329358900 15078199200 56997615100 Chemical analysis; Differential scanning calorimetry; Economic analysis; Heat storage; Latent heat; Melting point; Phase change materials; Polyethylene glycols; Polyethylenes; Reliability analysis; Solar energy; Thermal cycling; Thermal energy; Accelerated thermal cycles; Compositional stability; Differential scanning calorimeters; Latent heat of fusion; Organic phase change material (O-PCM); Techno- economic analysis; Thermal energy storage systems; Thermal reliability; Chemical stability Accelerated thermal cycle test of polyethylene glycol (PEG) of molecular weight 6000, an organic phase change material (O-PCM), has been carried out for 1500 melt/freeze cycles. The latent heat of fusion and melting temperature is measured using differential scanning calorimeter between 0th and 1500th melt-freeze cycles to study the changes in its thermal properties. Also, the changes in the compositional/functional groups of the material during the cycle test are also measured using FT-IR spectroscopy technique. The melting temperature is found to be stable in the quoted range of 55-60 �C with a maximum deviation of 6.5% when compared to that of at 0th cycle. However, a gradual drop in the latent heat of fusion with the increasing number of thermal cycles is measured. The FT-IR spectra do not show any noticeable changes in the peaks which confirm its compositional stability even after the higher number of thermal cycles. Thermal and chemical reliability tests of PEG 6000 along with the techno-economic analysis have shown that this PCM has a significant potential to be used as a thermal energy storage system. � 2015 Elsevier B.V. All rights reserved. Final 2023-05-29T06:12:25Z 2023-05-29T06:12:25Z 2016 Article 10.1016/j.solmat.2015.12.023 2-s2.0-84952359475 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84952359475&doi=10.1016%2fj.solmat.2015.12.023&partnerID=40&md5=61b4c603b0626ace468166ef4f050743 https://irepository.uniten.edu.my/handle/123456789/22815 147 235 239 Elsevier B.V. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Chemical analysis; Differential scanning calorimetry; Economic analysis; Heat storage; Latent heat; Melting point; Phase change materials; Polyethylene glycols; Polyethylenes; Reliability analysis; Solar energy; Thermal cycling; Thermal energy; Accelerated thermal cycles; Compositional stability; Differential scanning calorimeters; Latent heat of fusion; Organic phase change material (O-PCM); Techno- economic analysis; Thermal energy storage systems; Thermal reliability; Chemical stability |
author2 |
56424398200 |
author_facet |
56424398200 Sharma R.K. Ganesan P. Tyagi V.V. Mahlia T.M.I. |
format |
Article |
author |
Sharma R.K. Ganesan P. Tyagi V.V. Mahlia T.M.I. |
spellingShingle |
Sharma R.K. Ganesan P. Tyagi V.V. Mahlia T.M.I. Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage |
author_sort |
Sharma R.K. |
title |
Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage |
title_short |
Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage |
title_full |
Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage |
title_fullStr |
Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage |
title_full_unstemmed |
Accelerated thermal cycle and chemical stability testing of polyethylene glycol (PEG) 6000 for solar thermal energy storage |
title_sort |
accelerated thermal cycle and chemical stability testing of polyethylene glycol (peg) 6000 for solar thermal energy storage |
publisher |
Elsevier B.V. |
publishDate |
2023 |
_version_ |
1806426069973073920 |
score |
13.223943 |