Burner tilting angle effect on velocity profile in 700 MW utility boiler
Boiler firing; Boilers; Pulverized fuel fired boilers; Boiler operators; Design condition; Fire ball; Firing angle; Off designs; Tilting angle; Utility boiler; Velocity profiles; Coal fired boilers
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Physics Publishing
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-22477 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-224772023-05-29T14:01:14Z Burner tilting angle effect on velocity profile in 700 MW utility boiler Munisamy K.M. Yusoff M.Z. Thangaraju S.K. Hassan H. Ahmad A. 15035918600 7003976733 36633163200 7202560785 57220712712 Boiler firing; Boilers; Pulverized fuel fired boilers; Boiler operators; Design condition; Fire ball; Firing angle; Off designs; Tilting angle; Utility boiler; Velocity profiles; Coal fired boilers 700 MW of utility boiler is investigated with manipulation of inlet burner angle. Manipulation of burner titling angle is an operational methodology in controlling rear pass temperature in utility boilers. The rear pass temperature unbalance between right and left side is a problem caused by fouling and slagging of the ash from the coal fired boilers. This paper presents the CFD investigation on the 0� and -30� of the burner angle of the utility boiler. The results focusing on the velocity profile. The design condition of 0� burner firing angle is compared with the off-design burner angle -30� which would be the burner angle to reduce the rear pass temperature un-balance by boiler operators. It can be concluded that the -30� burner angle reduce the turbulence is fire ball mixing inside the furnace. It also shift the fire ball position in the furnace to reduce the rear pass temperature. Final 2023-05-29T06:01:14Z 2023-05-29T06:01:14Z 2015 Conference Paper 10.1088/1757-899X/88/1/012021 2-s2.0-84948432343 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84948432343&doi=10.1088%2f1757-899X%2f88%2f1%2f012021&partnerID=40&md5=8d7627e8cdcf885eb1a249467e53986d https://irepository.uniten.edu.my/handle/123456789/22477 88 1 12021 All Open Access, Gold Institute of Physics Publishing Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Boiler firing; Boilers; Pulverized fuel fired boilers; Boiler operators; Design condition; Fire ball; Firing angle; Off designs; Tilting angle; Utility boiler; Velocity profiles; Coal fired boilers |
author2 |
15035918600 |
author_facet |
15035918600 Munisamy K.M. Yusoff M.Z. Thangaraju S.K. Hassan H. Ahmad A. |
format |
Conference Paper |
author |
Munisamy K.M. Yusoff M.Z. Thangaraju S.K. Hassan H. Ahmad A. |
spellingShingle |
Munisamy K.M. Yusoff M.Z. Thangaraju S.K. Hassan H. Ahmad A. Burner tilting angle effect on velocity profile in 700 MW utility boiler |
author_sort |
Munisamy K.M. |
title |
Burner tilting angle effect on velocity profile in 700 MW utility boiler |
title_short |
Burner tilting angle effect on velocity profile in 700 MW utility boiler |
title_full |
Burner tilting angle effect on velocity profile in 700 MW utility boiler |
title_fullStr |
Burner tilting angle effect on velocity profile in 700 MW utility boiler |
title_full_unstemmed |
Burner tilting angle effect on velocity profile in 700 MW utility boiler |
title_sort |
burner tilting angle effect on velocity profile in 700 mw utility boiler |
publisher |
Institute of Physics Publishing |
publishDate |
2023 |
_version_ |
1806423495172685824 |
score |
13.222552 |