On-site OLTC monitoring using duval triangle and DWRM
Electric resistance; Electric resistance measurement; Insulation; Voltage control; Wear of materials; Winding; Dissolved gas analyses (DGA); Duval triangle methods; Insulation degradation; Insulation oil; OLTC; On-load tap changers; Visual inspection; Winding resistances; Oil filled transformers
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uniten.dspace-22420 |
---|---|
record_format |
dspace |
spelling |
my.uniten.dspace-224202023-05-29T14:00:52Z On-site OLTC monitoring using duval triangle and DWRM Khiar M.S.A. Ghani S.A. Chairul I.S. Thayoob Y.H.M. Ghazali Y.Z.Y. 55336341600 56504019900 55336864500 6505876050 55336569600 Electric resistance; Electric resistance measurement; Insulation; Voltage control; Wear of materials; Winding; Dissolved gas analyses (DGA); Duval triangle methods; Insulation degradation; Insulation oil; OLTC; On-load tap changers; Visual inspection; Winding resistances; Oil filled transformers Generally, the insulation degradation and contacts failure happened inside the On Load Tap Changer (OLTC). Besides, the OLTC performance can be dropped due to contact wear. Hence., the worn contact creates hotspots inside OLTC tank and affects the insulating oil. Due to this phenomenon, the insulating oil will degrade faster. Consequently, the whole unit of the transformer will be affected as well. Therefore, it is important to find new ways to detect the contacts wear inside the OLTC as it impacts the insulation oil and the age of the transformer. Thus, this paper demonstrates the application of Duval Triangle method during the diagnosis of OLTC to provide any significant indication related to the breakdown of OLTC. Besides, this paper introduced the advanced technique, Dynamic Winding Resistance Measurement (DWRM) to figure out the types and locations of faults occurred inside the OLTC. Finally, visual inspections will be carried out to validate the both results obtained from DGA and DWRM respectively. The analysis in this paper revealed that the findings from Duval Triangle method were similar to the outcomes carried out by DWRM. � 2014 IEEE. Final 2023-05-29T06:00:52Z 2023-05-29T06:00:52Z 2015 Conference Paper 10.1109/TIME-E.2014.7011621 2-s2.0-84922801825 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84922801825&doi=10.1109%2fTIME-E.2014.7011621&partnerID=40&md5=7a89837b2b6e43645525c188aab885f1 https://irepository.uniten.edu.my/handle/123456789/22420 7011621 216 221 Institute of Electrical and Electronics Engineers Inc. Scopus |
institution |
Universiti Tenaga Nasional |
building |
UNITEN Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tenaga Nasional |
content_source |
UNITEN Institutional Repository |
url_provider |
http://dspace.uniten.edu.my/ |
description |
Electric resistance; Electric resistance measurement; Insulation; Voltage control; Wear of materials; Winding; Dissolved gas analyses (DGA); Duval triangle methods; Insulation degradation; Insulation oil; OLTC; On-load tap changers; Visual inspection; Winding resistances; Oil filled transformers |
author2 |
55336341600 |
author_facet |
55336341600 Khiar M.S.A. Ghani S.A. Chairul I.S. Thayoob Y.H.M. Ghazali Y.Z.Y. |
format |
Conference Paper |
author |
Khiar M.S.A. Ghani S.A. Chairul I.S. Thayoob Y.H.M. Ghazali Y.Z.Y. |
spellingShingle |
Khiar M.S.A. Ghani S.A. Chairul I.S. Thayoob Y.H.M. Ghazali Y.Z.Y. On-site OLTC monitoring using duval triangle and DWRM |
author_sort |
Khiar M.S.A. |
title |
On-site OLTC monitoring using duval triangle and DWRM |
title_short |
On-site OLTC monitoring using duval triangle and DWRM |
title_full |
On-site OLTC monitoring using duval triangle and DWRM |
title_fullStr |
On-site OLTC monitoring using duval triangle and DWRM |
title_full_unstemmed |
On-site OLTC monitoring using duval triangle and DWRM |
title_sort |
on-site oltc monitoring using duval triangle and dwrm |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2023 |
_version_ |
1806424417287274496 |
score |
13.214268 |